#FactoryTalk
Your controller backups have a server. Who can reach it? Check AssetCentre's version, permitted clients, and independent recovery copy. Diagram + worksheet:
https://deceptioncheck.ai/blog/factorytalk-controller-backup-server
November 5, 2026 at 3:05 PM
🚨 EUVD-2019-19388
📊 8.5/10
🏢 rockwellautomation

📝 Studio 5000 Logix Designer 30.01.00 contains an unquoted service path vulnerability in the FactoryTalk Activation Service that allows local use...

🔗 https://euvd.enisa.europa.eu/vulnerability/EUVD-2019-19388

#cybersecurity #infosec #cve #euvd
October 27, 2026 at 2:02 AM
Rockwell Automation Enhances FactoryTalk with NVIDIA Nemotron for AI-Oriented Industrial Solutions#USA#Milwaukee#Rockwell_Automation#NVIDIA_Nemotron#FactoryTalk_Conductor
Rockwell Automation Enhances FactoryTalk with NVIDIA Nemotron for AI-Oriented Industrial Solutions
In its latest update, Rockwell Automation integrates NVIDIA Nemotron support into FactoryTalk Conductor, enhancing AI capabilities for industries seeking automation.
third-news.com
October 22, 2026 at 12:29 PM
Rockwell Automation Expands FactoryTalk Conductor with NVIDIA Nemotron Support

​ Manufacturers gain additional deployment flexibility for industrial AI orchestration through support for NVIDIA Nemotron models MILWAUKEE, Oct. 22, 2026 /PRNewswire/ -- Rockwell Automation, Inc. (NYSE: ROK), the…
Rockwell Automation Expands FactoryTalk Conductor with NVIDIA Nemotron Support
​ Manufacturers gain additional deployment flexibility for industrial AI orchestration through support for NVIDIA Nemotron models MILWAUKEE, Oct. 22, 2026 /PRNewswire/ -- Rockwell Automation, Inc. (NYSE: ROK), the world's largest company dedicated to industrial automation and digital transformation, today announced support for NVIDIA Nemotron open models within FactoryTalk® Conductor™, its AI-native orchestration platform for industrial automation. Building on the recent introduction of FactoryTalk Conductor, support for NVIDIA Nemotron models expands deployment flexibility for manufacturers adopting industrial AI.
ohsem.me
October 22, 2026 at 12:52 PM
Rockwell Automation's FactoryTalk Conductor: A Game-Changer for Industrial AI Integration#USA#AI_Integration#Milwaukee#Rockwell_Automation#FactoryTalk
Rockwell Automation's FactoryTalk Conductor: A Game-Changer for Industrial AI Integration
Rockwell Automation unveils FactoryTalk Conductor, a revolutionary AI-native orchestration platform aimed at enhancing industrial automation workflows.
third-news.com
October 21, 2026 at 11:06 AM
Rockwell Automation Unveils FactoryTalk Conductor: A Revolutionary AI Platform for Industrial Automation#USA#Milwaukee#Rockwell_Automation#Industrial_Automation#FactoryTalk_Conductor
Rockwell Automation Unveils FactoryTalk Conductor: A Revolutionary AI Platform for Industrial Automation
Rockwell Automation introduces FactoryTalk Conductor, an innovative AI orchestration platform designed to enhance industrial automation workflows seamlessly.
third-news.com
October 21, 2026 at 11:04 AM
Rockwell Automation Unveils AI-Native FactoryTalk Conductor Platform
Rockwell Automation on October 21, 2026 announced the introduction of FactoryTalk Conductor, an AI-native orchestration platform designed to coordinate AI-powered work across the industrial automation lifecycle. The software will make its public debut at Automation Fair 2026 in Boston, where attendees will receive a first look ahead of commercial availability planned for the first quarter of 2027. How the Platform Works FactoryTalk Conductor lets users initiate engineering tasks using natural language and connects the software, AI capabilities and workflows needed to complete them, the company said. Rockwell described the platform as creating a foundation for AI-enabled workflows from system design through operation and maintenance. At launch, it will integrate with Studio 5000 Logix Designer, Logix Echo, Emulate3D and FactoryTalk Optix, providing coverage across design, development, simulation and testing workflows. Integrations with FactoryTalk Design Studio, FactoryTalk Historian, Plex and Fiix are planned to follow. According to the announcement’s FAQ, a traditional AI copilot assists with individual tasks, while FactoryTalk Conductor enables multiple AI agents, workflows and software tools to work together across engineering processes. That structure, the company said, allows broader automation of complex, multi-step activities that span applications, data sources and teams. Customers can also create and deploy their own...
www.unite.ai
October 21, 2026 at 1:55 PM
FactoryTalk Conductor is a solid step toward bridging the OT/IT gap. The real magic will be how it orchestrates edge-to-cloud workflows without breaking existing control loops. Exciting shift! 🚀
October 21, 2026 at 9:21 PM
ロックウェル・オートメーション、RSLinx・Logix・FactoryTalkにわたる十数件の脆弱性を修正

ロックウェル・オートメーションは、産業施設で使用されているソフトウェアおよびコントローラーに存在していた十数件の脆弱性を修正しました。最も深刻な欠陥では、制御システムのコンポーネントを停止させたり、デバイス上でコードを実行したり、Windowsで SYSTEM権限を取得したりすることが可能でした。...
ロックウェル・オートメーション、RSLinx・Logix・FactoryTalkにわたる十数件の脆弱性を修正
ロックウェル・オートメーションは、産業施設で使用されているソフトウェアおよびコントローラーに存在していた十数件の脆弱性を修正しました。最も深刻な欠陥では、制御システムのコンポーネントを停止させたり、デバイス上でコードを実行したり、Windowsで SYSTEM権限を取得したりすることが可能でした。
blackhatnews.tokyo
September 7, 2026 at 2:16 PM
Rockwell Automation Patches Over a Dozen Vulnerabilities Across Products www.securityweek.com/rockwell-aut...
Rockwell Automation Patches Over a Dozen Vulnerabilities Across Products
The industrial giant has released advisories for its RSLinx Classic, ArmorStart, ControlFLASH, FactoryTalk, and other products.
www.securityweek.com
September 3, 2026 at 6:12 PM
🟠 HOCH · Rockwell Automation FactoryTalk Activation Manager und Historian Machine Edition: mehrere Schwachstellen

CERT-Bund (BSI)
Rockwell Automation FactoryTalk Activation Manager und Historian Machine Edition: mehrere Schwachst…
CERT-Bund (BSI) meldet mehrere Schwachstellen in Rockwell Automation FactoryTalk Activation Manager und Historian Machine Edition mit dem Schweregrad hoch. Die vollständige Beschreibung mit betroffen…
www.neonotu.com
September 2, 2026 at 10:08 PM
Latest post from CISA
Rockwell Automation FactoryTalk Activation Manager
View CSAF Summary The following versions of Rockwell Automation FactoryTalk Activation Manager are affected: FactoryTalk Activation Manager V5.02_and_below (CVE-2026-16675) CVSS Vendor Equipment Vulnerabilities v3 7.8 Rockwell Automation Rockwell Automation FactoryTalk Activation Manager Improper Restriction of Excessive Authentication Attempts Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-16675 A privilege escalation vulnerability exists within FactoryTalk Activation Manager. The vulnerability stems from custom actions in the installer that spawn visible console windows running with SYSTEM privileges during installation or repair operations. An authenticated attacker with Windows credentials could hijack these console windows to obtain a SYSTEM-level command prompt, allowing full access to all files, processes, and system resources. View CVE Details Affected Products Rockwell Automation FactoryTalk Activation Manager Vendor: Rockwell Automation Product Version: Rockwell Automation FactoryTalk Activation Manager V5.02_and_below Product Status: known_affected Remediations Vendor fix Rockwell Automation recommends users update to software version V5.03. Mitigation Customers using the affected software who are not able to upgrade to one of the corrected versions should use Rockwell Automation's security best practices. Relevant CWE: CWE-307 Improper Restriction of Excessive Authentication Attempts Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H 4.0 8.5 HIGH CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N Acknowledgments An anonymous security researcher reported this vulnerability to Rockwell Automation, who reported it to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-09-01 Date Revision Summary 2026-09-01 1 Initial republication of Rockwell Automation advisory Legal Notice and Terms of Use
www.cisa.gov
September 1, 2026 at 3:49 PM
Win11 26H2 build 26300.9278 is in Release Preview, not GA. Patch FactoryTalk Historian for CVE-2025-12768 RCE; RSLinx 4.50 has unpatched CIP DoS. Intune OS-build filters are GA. Explorer menus move custom commands. +11 more stories, 64 new members
Windows 11 26H2 Release Preview: Should You Join?
Windows 11 version 26H2 has entered the Release Preview Channel, but that does not make it generally available—or automatically suitable for every PC. Microsoft released build 26300.9278 to Release…
windowsforum.com
September 1, 2026 at 6:00 PM
Notícia da SecurityWeek

"Critical Flaws Patched in Rockwell FactoryTalk, Micro800, ControlLogix Products" #bolhasec
Critical Flaws Patched in Rockwell FactoryTalk, Micro800, ControlLogix Products
Rockwell Automation has published several advisories describing critical and high-severity vulnerabilities affecting its products.
www.securityweek.com
August 30, 2025 at 6:30 PM
Notícia da SecurityOnline

"CVE-2025-24480 (CVSS 9.8): Rockwell Automation Aborda Falha Crítica no FactoryTalk View ME" #bolhasec
CVE-2025-24480 (CVSS 9.8): Rockwell Automation Addresses Critical Flaw in FactoryTalk View ME
CVE-2025-24479 and CVE-2025-24480 could potentially allow attackers to execute malicious code and compromise affected systems.
securityonline.info
April 1, 2025 at 8:30 PM
January 12, 2025 at 6:13 AM
Rockwell Automation FactoryTalk®服务平台FTSP存在JWT验证绕过漏洞分析与应对策略

https://qian.cx/posts/BFE116C1-C106-4BD4-9D0D-20B8653E84A3
July 22, 2026 at 5:11 AM
Rockwell Automation FactoryTalk Historian Site Edition 安全漏洞分析与防护指南

https://qian.cx/posts/69B1433F-19DC-4EB4-955B-CDAC14F4ECBF
July 5, 2026 at 9:48 PM