#MicroLogix
Discover the Allen Bradley 1766-L32BWAA MicroLogix 1400 PLC Controller.

Featuring flexible digital and analog I/O, relay outputs, and Ethernet/serial communication, it's designed for industrial machine control and automation applications.

#allenbradley #rockwellautomation #outputs
November 4, 2026 at 10:38 AM
Water utilities lose their MicroLogix PLCs as attackers rewrite IPs and passwords. https://intel.threadlinqs.com/threat/TL-2026-4339?utm_source=bluesky #ThreatIntel #CVE_2017_16740 #CVE_2021_22681 #IOCONTROL
October 24, 2026 at 4:02 AM
Industrial Applications of the Allen-Bradley 1766-L32BXB PLC

The Allen-Bradley 1766-L32BXB PLC automates machinery, conveyors, and industrial processes for efficient and reliable operation.

www.asteamtechno.com/a-complete-g...

#industryprocess #rockwellautomation #plc #micrologix1400 #technology
October 23, 2026 at 9:38 AM
Default passwords on exposed PLCs let attackers lock operators out of US water systems. https://intel.threadlinqs.com/threat/TL-2026-2972 #ThreatIntel #July #MicroLogix #ICS
October 6, 2026 at 2:35 PM
Attacks on water and wastewater control devices in at least seven US states made it harder for workers to operate equipment.

Flood…

https://en.hacks.gr/chaker-mpikan-se-syskeyes-monadon-ydreysis-kai-apocheteysis-se-toylachiston-7-politeies-ton-ipa/

#WaterInfrastructure #WaterUtilities #MicroLogix
October 6, 2026 at 3:40 PM
 

Allen-Bradley 1769-IQ16 CompactLogix 16-Point 24 V DC SINK/SOURCE Digital Input Module is a high-reliability I/O brick designed for use with the Allen-Bradley CompactLogix and MicroLogix 150
https://www.plc-hub.com/product/allen-bradley-1769-iq16-compactlogix-16-point-24vdc-digital-input-module/
Allen-Bradley 1769-IQ16 | CompactLogix 16-Point 24VDC Digital Input Module
Allen-Bradley 1769-IQ16 CompactLogix 16-Point 24VDC Digital Input Module. 10–30 VDC, source/sink, DIN-rail or panel mount. In stock at plc-hub.com with worldwide shipping and full Allen-Bradley documentation.
www.plc-hub.com
September 11, 2026 at 9:40 AM
I have successfully secured some PLCs to play with, now I can bring the MicroLogix back to school!
April 18, 2026 at 9:50 AM
Free 11 part video course is available now on YouTube for programming Rockwell Automation MicroLogix controllers. youtube.com/playlist?lis...
Allen Bradley Micrologix 1000 PLC Programming Course - FREE - YouTube
This is a comprehensive and free online course that utilizes free software packages from Rockwell Automation to learn the basics of PLC programming. You will...
youtube.com
June 26, 2025 at 3:34 PM
Forescout found 4,000+ Rockwell and Allen-Bradley controllers exposed online, with some still visible in U.S. cities hit by recent water system attacks. Stale remote access and EtherNet/IP raise risk. #USA #RockwellAutomation #AllenBradley
Despite federal warnings, thousands of U.S. industrial controllers used in water systems remain exposed online
A new Forescout scan found more than 4,000 Rockwell Automation and Allen-Bradley controllers exposed on the internet, with 22 still visible in cities affected by recent attacks on U.S. water systems. The research highlights ongoing risks from public-facing EtherNet/IP devices, stale remote-access services, and possible exposure to CVE-2017-16740 on some MicroLogix 1400 systems. #RockwellAutomation #AllenBradley #MicroLogix1400 #CVE-2017-16740
www.hendryadrian.com
August 6, 2026 at 10:15 PM
🚨Cyberattacks targeting water utilities have hit at least 12 U.S. states as of August 5, 2026. The FBI, EPA, and CISA report tampering with PLCs including Rockwell Automation MicroLogix devices, affecting operations but not water quality. #Cybersecurity #WaterSafety
Full report from No Spin Media.
data.nospin.media
August 6, 2026 at 2:16 PM
A micrologix 1400?
May 20, 2026 at 4:04 AM
The Minnesota attackers may hold a better backup of your plant than you do
More than 30 Minnesota community water systems were hit by coordinated cyber activity against their operational technology on July 26 and 27; several lost remote control or deliberately cut it while operators contained the intrusion. The reporting since — including CSO’s own news analysis — has rightly chased two open questions: Who did it, and whether a shared weakness in Rockwell Automation MicroLogix 1400 controllers tied dozens of small utilities together. Both questions matter. Neither changes what operators must do this week. Attribution is the investigators’ problem. Exposure is yours — and the advisories published since July 30 contain considerably more actionable detail than most coverage has extracted from them. ## Key takeaways * **Assume the attackers have your control logic.** CISA’s advisory AA26-097A documents exfiltration of PLC project files. Rockwell’s recovery notice for locked-out MicroLogix 1400s requires a current offline project file to restore operations — an artifact many small utilities cannot produce. Where both are true, the adversary may hold the only current copy of the plant’s logic. * **You cannot Shodan your own cellular exposure.** Researchers found little internet-facing Minnesota water infrastructure precisely because these utilities connect over cellular. The same opacity blinds defenders’ self-assessments. Enumerate SIM-equipped OT devices from carrier invoices, not from network scans. * **Your integrator is part of your attack surface.** If a shared systems integrator or communications architecture connected the victims, the unit of compromise is not the utility — it is the integrator’s customer fleet. Ask yours which other customers share your remote-access design. * **Recovery is not resilience.** Braham was back in roughly two hours; Plymouth ran manually while cellular links were rebuilt. Time-to-manual is a testable metric, not an assumption. Test it. * **The first hardening steps are configuration, not procurement.** RUN mode at the keypad, the strongest password protection the firmware supports, HTTP server off, no public IP. The gap exposed in Minnesota is not knowledge. It is execution order under pressure. ## The asymmetry nobody is naming The most consequential sentence of the past week is buried in Rockwell’s July 30 notice SD1790. It is not a vulnerability disclosure — there is no CVE. The attackers did not exploit a flaw; they used the controller’s intended functionality. Changing an IP address is an administrative operation, and setting a password is a security feature — the malicious element was never the command, only who issued it, from where and against which physical process. What SD1790 actually is, is a recovery procedure for operators locked out of their own MicroLogix 1400s: Power the controller off, disconnect the battery, power-cycle into a fault state, reconnect. That sequence erases the program, the data and the IP configuration. Then, the notice says, redownload your project file. That instruction presumes you have one. Current. Offline. Matching what actually runs in the field after fifteen years of undocumented tweaks by three generations of technicians and two integrators. In my project work across energy and manufacturing, that assumption fails more often than any firewall — in one plant assessment, the only person who could have restored a controller had left the integrator two years earlier, and the project file left with him. Now cross-reference the federal advisory. AA26-097A has tracked this campaign since March; its July 22 update expanded the target set beyond Rockwell to Schneider Electric and Siemens devices, documented exfiltration of PLC project files for the first time and added detection guidance for manipulated reusable code modules embedded in PLC programs. No one has publicly confirmed exfiltration at the Minnesota utilities themselves — which is exactly why it belongs in your planning assumptions rather than your press statements. Read those two documents together and the strategic picture inverts: An adversary who may be able to study — or quietly modify — control logic that the owner cannot even restore. The countermeasure costs nothing but discipline. Treat control logic like source code. Every controller gets an offline, versioned, hash-verified project archive. Verification means uploading the running program and comparing it against the archive — not assuming the file on the engineering laptop is current. And widen the definition of backup: A rebuild-ready package includes firmware versions, HMI configuration, I/O lists, the vendor software with valid licenses, the right cable and a record of the last authorized change. NIST’s OT Backup Quick Start Guide, SP 1339, published in June, makes the same point in two pages: Create, test and review backups inside change management — otherwise they are storage, not capability. Schedule it like instrument calibration, not like an IT backup job, because that is the operational category it belongs to. ## You can’t Shodan a SIM One detail from the investigation deserves more attention than it received: Researchers scanning Minnesota’s public IP space found little obviously exposed water infrastructure. One plausible explanation, offered by researchers quoted in the initial coverage, is that many of these utilities communicate over cellular links — Plymouth’s disconnection of cellular-connected equipment confirms at least part of that picture — and cellular paths are far harder to enumerate from outside than internet-facing systems. Operators have drawn comfort from the wrong conclusion. Cellular opacity did not protect the victims; it merely hid the exposure from everyone, including themselves. If a security researcher cannot see your cellular attack surface, neither can your own assessment — and that is precisely the population that got hit. There is a mundane fix, and it is the one I run in my own asset-inventory workshops: Pull the carrier bill. Every modem generates an invoice line whether or not it appears on any diagram, and the invoice regularly surfaces devices that three network revisions missed. Reconcile every SIM against a named device, a named owner and a documented purpose. CISA’s July 30 alert told water utilities to check for undocumented cellular modems installed by operators, vendors or system integrators — and the word undocumented is the tell: The agency assumes your architecture diagram is wrong. Then move what remains behind a private APN or VPN termination, strip every public IP and port-forwarding rule and restrict management access to known engineering workstations. ## Your integrator is your blast radius The distributed character of this campaign is its most important feature. Dozens of geographically clustered utilities, hit in a two-day window, with neighboring infrastructure apparently untouched, points toward some common technical thread — a shared systems integrator, a shared communications architecture, a shared remote-access design. If that hypothesis holds, the defensive unit is no longer the individual utility. It is the integrator’s customer fleet. A standing vendor tunnel, replicated with the same design across forty small customers, converts one compromised contractor into forty compromised water systems. Here are the three questions I put to integrators in my own projects — ask yours this week: Which of your other customers share my remote-access architecture? Who at your firm can reach my controllers today, and are those individual identities or a shared account? Can I pull the session logs myself? Then change the model: Replace standing tunnels with just-in-time access — request-scoped, time-boxed, individually authenticated with a second factor, brokered through a jump host you control, recorded. And put a notification clause in the contract: If the integrator is compromised, you hear about it in hours, not from the FBI. ## Minnesota’s fast recoveries were earned, not lucky Braham’s water plant was back under operator control in roughly two hours, with no boil-water order. Plymouth’s operators switched to manual operation and disconnected the compromised cellular equipment at two water towers and fourteen lift stations, keeping service running until communications were restored. None of that was produced by a security product; it was produced by operating capability that existed before the attack needed it. Restoring the screens is not the finish line, either: After an unauthorized hand has changed a controller’s configuration, the first recovery question is not whether the HMI is back online but whether you can trust what it is telling you — which means verifying levels, pressures and pump states against local indicators before the display regains its authority. Manual operation is a designed capability, not a folk memory. It requires procedures that exist on paper — literally on paper, because the HMI may be what you just lost — people trained on them, and decision rights assigned in advance. The sector had, in fact, just rehearsed this: EPA’s 2026 National Cyber Drill on July 8 — 18 days before Minnesota — put utilities through precisely that scenario, operating with SCADA remote connectivity, cloud services and communications degraded or unavailable. Whether that capability actually exists at your site is testable: I’ve published a free, browser-based Island Mode 72-hour stress test — one of six no-signup companion tools I maintain openly on GitHub — that walks a site through exactly this question, from credential caches to offline backups. Joint guidance issued by CISA with its Australian, British and Canadian counterparts in late July makes the same point at doctrine level: Maintain isolation and recovery plans so essential services continue under degraded conditions, through manual or alternative SCADA paths. The decision-rights half is the part most plans skip. Which systems may a SOC or an MSSP isolate unilaterally, and which require the operator who understands the process? That is the containment paradox I wrote about in these pages two weeks ago, and the water-sector version is identical: The artifact is one page, the conversation that produces it takes an afternoon, and the absence of it is what turns a two-hour incident into a two-day one. ## The response calendar **Within 72 hours:** Kill every direct external path and public IP, pull the carrier bill and flag every SIM you cannot map to a device, preserve gateway and engineering-workstation logs, verify the physical process against local indicators and upload the running logic from each critical controller to compare against your archive. **Within 30 days:** Finish the SIM-to-asset reconciliation, rotate every credential that ever traveled through an exposed path, give every third party an individual identity with session logging and assemble a rebuild-ready package — project file, firmware version, HMI configuration, software, cable — for each critical controller. **Within one quarter:** Run a factory-reset recovery drill on a representative controller, measure time-to-manual in a live exercise, replace the last standing vendor tunnel with just-in-time access, put the notification clause into integrator contracts and get the containment matrix — who may isolate what — signed. ## 5 numbers to know by Friday 1. SIM-equipped OT endpoints on your carrier invoice versus devices in your asset register. Any delta is unmanaged attack surface. 2. Controllers still running default, blank or shared passwords. After this month, that number is a decision, not an oversight. 3. Days since the last verified offline project-file backup, per controller. Verified means uploaded and compared — not assumed. 4. Tested time-to-manual, per site. Measured in a drill, with the people actually on shift, not estimated in a workshop. 5. Third parties with standing access paths into your OT. The target is zero. Everything else becomes just-in-time. Attribution may firm up, or the ambiguity may itself be the point — it serves the attacker either way. The five numbers above will not tell you who attacked Minnesota. They tell you how much room the next attacker has inside your plant. The next campaign gets to learn from this one. Attribution can wait. Your exposure math cannot. **This article is published as part of the Foundry Expert Contributor Network.** Want to join?
www.csoonline.com
August 4, 2026 at 12:27 PM
夜行性インコさんのまとめ『Rockwell Automation/Allen-Bradley製PLC「MicroLogix」1100・1400シリーズ』がやられたようす:米国ミネソタ州の水道システムへのサイバー攻撃についてまとめてみた - piyolog piyolog.hatenadiary.jp/entry/2026/0...
米国ミネソタ州の水道システムへのサイバー攻撃についてまとめてみた - piyolog
2026年7月28日、米国ミネソタ州の情報システムを所管するMinnesota IT…
piyolog.hatenadiary.jp
August 3, 2026 at 12:45 AM
1762-L24BXB New Factory Sealed AB 1762-L24BXB  MicroLogix1200 24 Point Controller
Technical specifications for 1762-L24BXB

Manufacturer
Rockwell Automation

Power Supply Usage
40W

Shipping Weight
2.4 pounds

Dimensions
Height: 90 mm 104 mm (with #1762L24BXB
www.plc-hub.com/product/1762...
1762-L24BXB Allen Bradley
The Allen-Bradley 1762-L24BXB is a MicroLogix 1200 Programmable Logic Controller (PLC). This controller has Ten (10) standard 24VDC inputs, Four (4) Fast 24VDC inputs, Five (5) relay, Four (4) 24VDC FET and One (1) high-speed output. For communication, it has an embedded 8-pin mini-DIN communication port supporting DF1, DH-485, ASCII, MODBUS protocols.
www.plc-hub.com
January 22, 2025 at 7:51 AM
MicroLogix 1200 Programmable Controllers User Manual
www.plc-hub.com/micrologix-1...
MicroLogix 1200 Programmable Controllers User Manual
MicroLogix 1200 Programmable Controllers User Manual
www.plc-hub.com
January 22, 2025 at 7:50 AM