#Volumetric-Modulated
💥A Comparative Analysis of Virtual 2D VMAT-Based SFRT and 3D Lattice Radiotherapy: Evaluation of Dosimetric and Therapeutic Outcomes 💥

doi.org/10.31661/jbp...

#JBPE #Spatially Fractionated Radiotherapy #Volumetric-Modulated Arc Therapy
doi.org
September 9, 2026 at 9:23 AM
calibration curves on brain cancer treatment plans. Three calibration curves were compared: CIRS phantom-derived, Catphan phantom-derived, and the default curve in the Monaco Treatment Planning System. Ten volumetric modulated arc therapy (VMAT) plans [2/5 of https://arxiv.org/abs/2504.16805v1]
April 24, 2025 at 6:14 AM
Medicina, Vol. 61, Pages 483: Dose Escalation in Neoadjuvant Chemoradiotherapy for Rectal Cancer: Short-Term Efficacy and Toxicity of VMAT–SIB vs. 3D-CRT
Background and Objectives: The standard treatment for locally advanced rectal cancer (LARC) includes neoadjuvant chemoradiotherapy (nCRT), followed by surgery with or without adjuvant chemotherapy (CT). This study evaluated the efficacy and safety of dose-escalated radiotherapy (RT) using the volumetric modulated arc therapy–simultaneous integrated boost (VMAT–SIB) technique in patients with LARC compared to 3D conformal radiotherapy (3D-CRT). Materials and Methods: This study prospectively enrolled 75 patients with LARC. All patients received nCRT using VMAT–SIB, delivering a tumor dose (TD) of 54 Gy in 25 fractions, with concomitant CT following the 5-fluorouracil and leucovorin (5-FU–LV) protocol. To compare the treatment outcomes and toxicity associated with the increased RT dose, a retrospective cohort of 62 patients treated with the 3D-CRT technique was analyzed. The 3D-CRT group received a TD of 50.4 Gy in 28 fractions with the same CT. Outcomes, including pathological complete response (pCR), tumor regression grade (TRG), and sphincter preservation rates, were compared. Results: Among operated patients, the group treated with VMAT–SIB demonstrated improved rates of pCR (20.6% vs. 8.9%), with a statistically significant trend (p = 0.06). Sphincter-preserving surgeries were performed in 49 out of 63 operated patients (77.8%) in the VMAT–SIB group, compared to 35 out of 56 (62.5%) in the 3D-CRT group. Analysis of the definitive postoperative stage revealed a significantly higher prevalence of lower T categories (T0–2) (p < 0.01), negative N status (p < 0.05), and lower stages (I + II) (p < 0.05) in patients treated with the intensified RT approach. However, no significant differences in acute toxicity were observed. Conclusions: The implementation of intensified treatment with a higher dose using the VMAT–SIB technique demonstrated significant benefits in downsizing and downstaging compared to the standard treatment approach. These findings support its integration into clinical practice. However, further prospective, multi-center studies are needed to validate these results and assess long-term outcomes.
www.mdpi.com
March 11, 2025 at 1:33 AM
NOTABLE ARTICLE, June 2026 #JACMP: Automatic adaptive radiotherapy triggering based on CBCT using deep learning for esophageal cancer underwent volumetric modulated arc therapy
https://ow.ly/I0L650ZwFl5

Please join us in congratulating Juebin Jin et al, whose article was selected.
August 8, 2026 at 5:00 PM
NOTABLE ARTICLE, December 2025 #MedicalPhysics: Feasibility of markerless real‐time tumor tracking volumetric modulated arc therapy using diaphragm‐based respiratory offset vectors
https://ow.ly/84xk50XNeVk

Please join us in congratulating Mitsuhiro Nakamura et al, whose article was selected
January 1, 2026 at 2:02 PM
がんの放射線治療について、興味深い研究がありました。

Feng氏らの論文によると、あらゆる角度から立体的に放射線を当てる「4π照射」により、骨盤の骨髄への被曝を抑え、血液細胞が減る副作用リスクを低減できるとのこと。

照射角度の計算最適化で正常な組織を守る発想が、非常にスマートだと感じます。

出典: [URL]

実務で当たり前になるまで、しばらくかかりそうだ。

#医療Tech
4$π$ Planning for the Reduction of Predicted Hematologic Toxicity Risk in Cervical Cancer Radiotherapy
Purpose: In conventional coplanar radiotherapy for cervical cancer, nearby pelvic bones receive high radiation doses, increasing the risk of acute hematologic toxicity (HT). This study aims to estimate the HT risk reduction achievable with non-coplanar (4$π$) radiotherapy. Methods: We retrospectively analyzed 114 cervical cancer patients treated with coplanar volumetric modulated arc therapy (VMAT) between 2021 and 2023. Radiomic features from planning CTs were extracted and combined with clinical and dosimetric data to train predictive machine learning models. Patients were then replanned using integrated non-coplanar beam orientation and fluence map optimization (4$π$ planning). The top performing model was applied to these new plans to evaluate potential HT reduction. Results: Models combined radiomics, clinical, and dosimetric features achieved the highest predictive performance (AUC = 0.79). Feature importance analysis highlighted CT radiomic and dosimetric variables as the strong
arxiv.org
August 15, 2026 at 11:01 AM
子宮頸がんの放射線治療で、副作用を減らす工夫についての研究。

Haotian Feng氏らの論文によると、照射角度を立体的に分散させる「4π照射」により、骨盤の骨への被曝を抑え、血液細胞が減る副作用リスクを低減できると試算されています。

照射角度の最適化という計算技術の進歩が、患者さんの身体への負担軽減に直結する点が興味深いところです。

実務で当たり前になるまで、しばらくかかりそうだ。

出典: [URL]
#医療技術
4$π$ Planning for the Reduction of Predicted Hematologic Toxicity Risk in Cervical Cancer Radiotherapy
Purpose: In conventional coplanar radiotherapy for cervical cancer, nearby pelvic bones receive high radiation doses, increasing the risk of acute hematologic toxicity (HT). This study aims to estimate the HT risk reduction achievable with non-coplanar (4$π$) radiotherapy. Methods: We retrospectively analyzed 114 cervical cancer patients treated with coplanar volumetric modulated arc therapy (VMAT) between 2021 and 2023. Radiomic features from planning CTs were extracted and combined with clinical and dosimetric data to train predictive machine learning models. Patients were then replanned using integrated non-coplanar beam orientation and fluence map optimization (4$π$ planning). The top performing model was applied to these new plans to evaluate potential HT reduction. Results: Models combined radiomics, clinical, and dosimetric features achieved the highest predictive performance (AUC = 0.79). Feature importance analysis highlighted CT radiomic and dosimetric variables as the strong
arxiv.org
August 14, 2026 at 12:31 PM
arXiv:2503.23313v1 Announce Type: new
Abstract: In this paper, we introduce SpINR, a novel framework for volumetric reconstruction using Frequency-Modulated Continuous-Wave (FMCW) radar data. Traditional radar imaging techniques, such as [1/6 of https://arxiv.org/abs/2503.23313v1]
April 2, 2025 at 6:06 AM