#f83d099cd63
Air to Ground Message:

Hi maintrol already pack 2 regul fault add in climb cabin zone duct temp 60C switched pack 2 off to stop cabin temp rising do we need engr or acf

Area: Portsmouth, UK
Type: Airbus A320
A: #aa1dc35e509
F: #f83d099cd63
September 10, 2026 at 6:53 AM
Air to Ground Message:

HI MAINTROL ALREADY PACK 2 REGUL FAULT ADD IN CLIMB CABIN ZONE DUCT TEMP 60C SWITCHED PACK 2 OFF TO STOP CABIN TEMP RISING DO WE NEED ENGR OR ACF

Area: Portsmouth, UK
Type: Airbus A320
A: #aa1dc35e509
F: #f83d099cd63
September 10, 2026 at 6:53 AM
Air to Ground Message:

EZY WENT TECH BEHIND US

Area: Portsmouth, UK
Type: Airbus A321
A: #aa9936d9a9e
F: #f83d099cd63

#acars #vdlm2
March 28, 2026 at 8:19 AM
Air to Ground Message:

NOW HAVE AIR X-BLEED FAULT. PUT IN MANUAL. WONT CLOSE BUT WILL OPEN REQUEST ENGINNERS IN AGP ETA 0930Z

Area: Jersey, UK
Type: Airbus A321
A: #ac804d2a3c4
F: #f83d099cd63

#acars #vdlm2