#recloser
I'm a bit of an expert in protection engineering, so I guess I should be fired and the garbage man should start developing recloser settings. I'm sure that'll end with no additional deaths or forest fires.

And in the meantime I'll start driving the garbage truck.
RFK Jr: We need to stop trusting the experts... Trusting the experts is not a feature of science or democracy, it's a feature of religion and totalitarianism.
August 30, 2025 at 11:30 PM
haha quick 2 second power outage followed by the delayed pop of a recloser operating way off in the distance
August 23, 2025 at 5:58 AM
Hot take here, if you don't know the importance of voltage management or fuse recloser coordination you probably should be measured about grid edge resilience too if you're arguing for greater renewable penetration
"grids need to adapt to a more decentralised, digitalised and flexible electricity system with millions of rooftop solar panels and local energy communities sharing resources." = reliability and resiliency will possibly come from the grid-edge 🤷‍♂️

www.europarl.europa.eu/news/en/pres...
MEPs push for more coordination and resilience in European electricity grids | News | European Parliament
MEPs adopted proposals for enhancing grid resilience, integrating renewable energy sources, and simplifying processes to meet the EU's energy goals.
www.europarl.europa.eu
May 14, 2025 at 12:28 PM
Pad mounted remote operated switch gear. Is it a recloser or just a remote isolation switch?
July 22, 2025 at 11:43 PM
*possible* but I would assume a recloser/fuse would pop by that point. Protection is designed to trip out in case of flickering like that normally.
January 11, 2025 at 3:27 AM
That's basically to stop a circuit breaker or recloser from closing in on a circuit that's still energized but not synchronized. Closing in out of phase is bad news, and the even worse bit is that in a situation of inverters vs the big grid, the big grid wins and your inverter fries.
August 29, 2025 at 12:23 AM
when your power goes out and you hear a bang, its almost never a transformer blowing up. its either a fuse cutout blowing (if it stays out) or a recloser temporarily interrupting the power when a fault is detected and turning it back on)

both are very loud
August 23, 2025 at 6:05 AM
i was so stupid back then, this is a recloser
owo?

*opens your motor operated line disconnect*
July 25, 2026 at 12:41 AM
🔄 Electronic Recloser Market grows with smart grid protection and automation investments. #ElectronicRecloser #SmartGrid #Utilities
www.marketresearchfuture.com/reports/elec...
June 27, 2026 at 9:50 AM
TIL about "unintentional islanding": scary stuff!

TL;DR: subcircuits stay energized (e.g. by distributed PV) when the utility opens a recloser, unbeknownst to the them, endangering workers and the general public 😬

www.nrel.gov/docs/fy22ost...
www.nrel.gov
March 4, 2025 at 5:19 PM
slowly failing insulator, no immediate concern, will just trip out a fuse/recloser upstream at some point. If the noise becomes disruptive, contact the utility; they won't approve replacement until they have documented customer complaints first.
March 2, 2026 at 2:36 AM
The local volt var control also says nothing about if the protection systems and fuse recloser coordinations are safe and these are a major *must have* in the operation of the system. Just as much as the voltage and thermals
May 1, 2025 at 1:03 PM
Worst I’ve seen was a line sitting on snow. Pulls some amps but not enough to trip the recloser. And if it’s an ungrounded system there’s no good path to substation neutral, which makes it even worse.
November 13, 2024 at 5:39 PM
my talking-out-of-my-ass guess is that there was a transient fault somewhere on the grid that either resolved itself or was routed around. for example, a recloser is basically like the circuit breaker in your house, but for the power company, and it resets itself after it trips: