#tonometry
Ophthopedia Update: IOP monitoring with an implantable sensor predicts visual field progression in the EYEMATE-IO trial: WHAT IS ALREADY KNOWN ON THIS TOPIC

*

Intraocular pressure (IOP) is the main modifiable risk factor for glaucoma progression, but… #Ophthalmology #Ophthotwitter #BJO
IOP monitoring with an implantable sensor predicts visual field progression in the EYEMATE-IO trial
WHAT IS ALREADY KNOWN ON THIS TOPIC * Intraocular pressure (IOP) is the main modifiable risk factor for glaucoma progression, but conventional in-office measurements provide only intermittent snapshots and may not reflect long-term IOP exposure.WHAT THIS STUDY ADDS * Higher mean IOP measured continuously with an implantable sensor was significantly associated with faster visual field progression, whereas mean IOP measured by in-office Goldmann applanation tonometry was not.HOW THIS STUDY MIGHT AFFECT RESEARCH, PRACTICE OR POLICY * Long-term continuous IOP monitoring may provide clinically relevant information beyond conventional office measurements and could improve risk stratification and individualised glaucoma management.Introduction Glaucoma is a chronic optic neuropathy characterised by progressive and irreversible visual field (VF) loss, which leads to a measurable decline in vision-related quality of life if left untreated.1 Although the primary goal of glaucoma management is to preserve visual function and maintain vision-related quality of life throughout the patient’s lifetime,
dlvr.it
November 16, 2026 at 5:46 PM
Remote home tonometry captures clinically meaningful IOP fluctuations that routine in-office evaluations miss, identifying progression risk in patients previously assumed to be stable, according to research published in Ophthalmology.

Learn more: https://bit.ly/4A7rIz8
Home Intraocular Pressure Device Predicts Visual Field Loss in Glaucoma
A home glaucoma monitoring device can predict visual field progression in patients with open-angle glaucoma.
bit.ly
November 3, 2026 at 5:56 PM
Ophthopedia Update: Defining the optimal duration of remote home tonometry for accurate characterization of intraocular pressure fluctuation: To determine the minimal duration of remote intraocular pressure (IOP) monitoring needed to yield accurate IOP… #Ophthalmology #ophthotwitter #eyecare
Defining the optimal duration of remote home tonometry for accurate characterization of intraocular pressure fluctuation
To determine the minimal duration of remote intraocular pressure (IOP) monitoring needed to yield accurate IOP fluctuation metrics in patients.
dlvr.it
November 2, 2026 at 7:17 PM
Ophthopedia Update: At-home IOP-measuring device decreased anxiety, increased confidence: Home tonometry devices were linked to decreased patient anxiety and increased doctor confidence, although financial cost and skepticism about reliability remain major barriers, according to data published in…
At-home IOP-measuring device decreased anxiety, increased confidence
Home tonometry devices were linked to decreased patient anxiety and increased doctor confidence, although financial cost and skepticism about reliability remain major barriers, according to data published in Journal of Glaucoma. “While the potential of [home tonometry] is evident, this technology has not been broadly integrated into clinical practices, despite its conception dating back over half a century,” Jeffrey Liu, MD, of the department of ophthalmology at Duke University Medical Center, and colleagues wrote. “The limited adoption of [home tonometry] suggests that
dlvr.it
October 13, 2026 at 8:24 PM
Ophthopedia Update: Assessment of the Necessity for High-Level Disinfection (HLD) of Reusable Ophthalmic Devices: A Multisociety Position Paper: Regulatory agencies in the United States and abroad are increasingly citing clinics and surgical facilities for… #Ophthalmology #ophthotwitter #eyecare
Assessment of the Necessity for High-Level Disinfection (HLD) of Reusable Ophthalmic Devices: A Multisociety Position Paper
Regulatory agencies in the United States and abroad are increasingly citing clinics and surgical facilities for what they deem to be inadequate disinfection of Goldmann applanation tonometry (GAT) tips, gonioscopy lenses, laser lenses, and other reusable clinic devices that contact the ocular surface. These regulators require routine high-level disinfection (HLD) of these reusable devices to prevent infection transmission. A multisociety task force formed to assess the necessity of HLD found no published evidence that these devices transmit sight-threatening infections or that HLD reduces infection transmission compared with lower-level disinfection methods.
dlvr.it
October 9, 2026 at 9:36 PM
Ophthopedia Update: Comment on: Ocular Response Analyzer versus Goldmann Applanation Tonometry in a Population-based Sample: The Thessaloniki Eye Study.: We read with great interest the article entitled “Ocular Response Analyzer versus Goldmann Applanation… #Ophthalmology #Ophthotwitter #Scicomm
Comment on: Ocular Response Analyzer versus Goldmann Applanation Tonometry in a Population-based Sample: The Thessaloniki Eye Study.
We read with great interest the article entitled “Ocular Response Analyzer versus Goldmann Applanation Tonometry in a Population-based Sample: The Thessaloniki Eye Study” by Bartzoulianou et al.(1) We congratulate the authors on this interesting population-based study. We would respectfully like to ask for clarification regarding a possible statistical inconsistency in the reported relationship between central corneal thickness (CCT) and intraocular pressure measured by Goldmann applanation tonometry (GAT-IOP).
dlvr.it
October 9, 2026 at 6:17 AM
Ophthopedia Update: Reply to Comment on: Ocular Response Analyzer versus Goldmann Applanation Tonometry in a Population-based Sample: The Thessaloniki Eye Study: We thank Drs Sakarya and Sakarya for their careful reading of our article and for identifying… #Ophthalmology #Ophthotwitter #Scicomm
Reply to Comment on: Ocular Response Analyzer versus Goldmann Applanation Tonometry in a Population-based Sample: The Thessaloniki Eye Study
We thank Drs Sakarya and Sakarya for their careful reading of our article and for identifying this discrepancy. We re-examined the linear regression analysis of the association between central corneal thickness (CCT) and GAT-IOP. The regression coefficient and 95% confidence interval reported in the article were correct (β = 0.015 mmHg per μm; 95% CI, 0.009–0.022). However, the reported P value of .02 was a reporting error. Using the unrounded model estimates, the exact P value was 1.42 × 10⁻⁶ (SE = 0.00316; t = 4.86; 840 degrees of freedom); therefore, the result should have been reported as P < .0001.
dlvr.it
October 8, 2026 at 6:20 PM
Ophthopedia Update: In-office and remote intraocular pressure metrics associated with visual field progression in treated open-angle glaucoma: To evaluate the association between various intraocular pressure (IOP) metrics and visual field progression in… #Ophthalmology #ophthotwitter #eyecare
In-office and remote intraocular pressure metrics associated with visual field progression in treated open-angle glaucoma
To evaluate the association between various intraocular pressure (IOP) metrics and visual field progression in open-angle glaucoma (OAG), when derived from in-office or remote (home) tonometry.
dlvr.it
September 30, 2026 at 6:30 PM
Ophthopedia Update: Potential Overestimation of Uveoscleral Outflow from Goldmann Tonometry Bias #Ophthomology #Eye #Ophthotwitter
Potential Overestimation of Uveoscleral Outflow from Goldmann Tonometr | OPTH | Dove Medical Press
Goldmann applanation tonometry underestimates manometric intraocular pressure by about 4–5 mmHg
dlvr.it
September 24, 2026 at 9:18 AM
Ophthopedia Update: Guidelines for Disinfection of Applanation Tonometers: A Position Statement from the American Glaucoma Society and the American Academy of Ophthalmology: Glaucoma is the leading cause of irreversible blindness in the United States and across the globe. Accurate measurement of…
Guidelines for Disinfection of Applanation Tonometers: A Position Statement from the American Glaucoma Society and the American Academy of Ophthalmology
Glaucoma is the leading cause of irreversible blindness in the United States and across the globe. Accurate measurement of intraocular pressure (IOP) is essential for management. As such, equitable access to accurate and high-quality tonometry to measure IOP is critical. In the 1950s, the Goldmann applanation tonometer (GAT) replaced the Schiotz tonometer as the clinical reference standard for measuring IOP. Current disinfection guidelines, using a categorization system devised in the 1930s, place tonometers in the same category as tonometers with instruments such as endoscopes and bronchoscopes, the latter of which contact the mucous membranes, as semi-critical instruments, requiring them to undergo high-level disinfection (HLD).
dlvr.it
September 17, 2026 at 9:17 PM
Updated archetype Intraocular pressure test [0.​0.​1-alpha]: - Modifications based on 2nd review
- Added use statements on expected result elements, self-tonometry, use of tonometry device details
- added reference to EGS Guidelines&terminology
- added examples to Interpretation
-
Archetype Intraocular pressure test (openEHR-EHR-OBSERVATION.intraocular_pressure.v0)
openEHR Clinical Knowledge Manager
ckm.openehr.org
September 3, 2026 at 4:40 PM
(They’re numbing drops. They always feel so gross and weird after. The test is called “applanation tonometry” in case you’re ever on Jeopardy and need to know) 🫡
June 18, 2026 at 3:56 PM
I once went to a fancy Warby Parker and they used a Rebound tonometry thingy, like a small ball that bounce of your eye instead of the puff of air, it was weirdly but not as startling somehow!
August 18, 2024 at 12:01 AM
My second least favorite thing at the eye doctor (tonometry is the least favorite).
February 5, 2025 at 2:34 PM
Prediction of perimetric progression in ocular hypertension and open angle glaucoma based on corneal biomechanics

European Journal of Ophthalmology, Ahead of Print.
PurposeTo identify parameters that are significant risk predictors of visual field (VF) progression in patients with ocular hyperte
Prediction of perimetric progression in ocular hypertension and open angle glaucoma based on corneal biomechanics
European Journal of Ophthalmology, Ahead of Print. PurposeTo identify parameters that are significant risk predictors of visual field (VF) progression in patients with ocular hypertension (OHT) or early primary open-angle glaucoma (POAG), using Goldmann applanation tonometry intraocular pressure (IOP-GAT),...
journals.sagepub.com
May 8, 2025 at 5:28 AM
Angle-Closure GlaucomaMarket – GlobalMarket - Industry Trends and Forecast to 2028| Data Bridge Market Research www.databridgemarketresearch.com/reports/glob...
Angle-Closure GlaucomaMarket – GlobalMarket - Industry Trends and Forecast to 2028| Data Bridge Market Research
Global Angle-Closure Glaucoma Market By Diagnosis (Gonioscopy, Tonometry, Ophthalmoscopy, Others), Treatment (Surgery, Medication, Others), Route of Administration (Oral, Parenteral, Ocular, Others), ...
www.databridgemarketresearch.com
February 17, 2025 at 5:05 PM
And what's interesting about that, is that this hardcoding of expected facial geometries can be subverted so easily.

Here's another way to do it: put someone's head in an tonometry immobilization rig, like with a glaucoma test:
April 28, 2024 at 12:27 PM
Led by Dr. Frederik Massie, this study demonstrates the feasibility of incorporating a single-lead #EEG device for automated sleep staging in a peripheral arterial tonometry-based home sleep apnea testing setup. academic.oup.com/sleep/advanc...
The evaluation of a novel single-lead biopotential device for home sleep testing
AbstractStudy Objectives. This paper reports on the clinical evaluation of the sleep staging performance of a novel single-lead biopotential device.Methods
academic.oup.com
December 12, 2024 at 8:07 PM
@sabotek tonometry - it checks inter optic pressure
December 1, 2024 at 9:14 PM
...including brachial flow-mediated dilation (FMD), hand microvascular reactivity (Flowmetry Laser Doppler, FLD), and finger reactive hyperemia index (Peripheral Arterial Tonometry, RHI).
June 14, 2025 at 1:01 AM
Cardiovascular Adaptation in Normal Pregnancy With 2D and 3D Echocardiography, Speckle Tracking, and Radial Artery Tonometry #JACCAdvances
www.jacc.org/doi/10.1016/...
#CardioObstetrics
November 12, 2024 at 7:58 PM