#MassSpecRSS
(Clin Chim Acta) One clone, one mass: The rise of mass spectrometry in the diagnosis and monitoring of monoclonal gammopathies: Publication date: Available online 14 November 2026

Source: Clinica Chimica Acta

Author(s): Gema García de la Rosa, Silvia de las Heras… #ClinChemActa #MassSpecRSS
One clone, one mass: The rise of mass spectrometry in the diagnosis and monitoring of monoclonal gammopathies
Publication date: Available online 14 November 2026 Source: Clinica Chimica Acta Author(s): Gema García de la Rosa, Silvia de las Heras Flórez, Cristina Agulló, Noemí Puig
dlvr.it
November 16, 2026 at 3:07 AM
(BioRxiv All) MeXalign - A Segmentation Mask-Based Registration Pipeline for Multimodal Single-Cell Analysis: Leveraging the power of multimodal imaging relies on accurate coregistration of yet fundamentally different modalities. Reliable cell-to-cell correspondence is… #BioRxiv #MassSpecRSS
MeXalign - A Segmentation Mask-Based Registration Pipeline for Multimodal Single-Cell Analysis
Leveraging the power of multimodal imaging relies on accurate coregistration of yet fundamentally different modalities. Reliable cell-to-cell correspondence is especially challenging as consecutive tissue sections do not necessarily contain identical cells or cellular structures. Here we present MeXalign, a segmentation-mask-based coregistration pipeline designed to integrate multimodal images acquired sequentially from the same specimen at single-cell resolution. Single-cell segmentation masks provide a modality-independent representation of cellular morphology and spatial organization. MeXalign was tested based on the two platforms, laser ablation inductively coupled plasma time-of-flight mass spectrometry (LA-ICP-TOFMS) and immunofluorescence (IF) microscopy. As a prerequisite, each modality integrates membrane and/or nucleus labels for accurate segmentation. The added value of MeXalign was highlighted for imaging of cell models deposited on glass slides and tissue sections. The performance of coregistration was validated on cytospins, murine tumor and human skin samples. A dedicated scoring system was introduced allowing to assess the quality of image coregistration. The robustness towards under-segmentation and downstream image analysis was evaluated on LA-ICP-TOFMS with and without coregistration, investigating metal drug uptake, barcoding and cellular phenotyping. A showcase study on cancer cells exposed to nanoparticles proved the accuracy, as the nanoparticle distribution was preserved at a subcellular level when using MeXalign. While all examples show the overall improved quality of segmentation, other benefits of complementary labelings can be anticipated, especially for cellular features unique to one modality.
dlvr.it
November 16, 2026 at 5:06 PM
(A Chem) GlycanPRMQuant: Automated Identification and Quantification of Permethylated N -Glycans from LC-PRM-MS/MS Data: AbstractTargeted parallel reaction monitoring (PRM) mass spectrometry enables sensitive and reproducible glycan quantification, but data analysis for permethylated… #MassSpecRSS
GlycanPRMQuant: Automated Identification and Quantification of Permethylated N -Glycans from LC-PRM-MS/MS Data
AbstractTargeted parallel reaction monitoring (PRM) mass spectrometry enables sensitive and reproducible glycan quantification, but data analysis for permethylated N-glycans currently relies on manual adaptation of proteomics tools such as Skyline combined with GlycoWorkbench for transition curation. This workflow requires extensive user intervention for fragment validation, isobaric disambiguation, and peak integration, limiting throughput and introducing operator-dependent variability. We present GlycanPRMQuant, an open-source Python pipeline that integrates precursor-glycan matching, fragment-level MS/MS annotation, automated isobaric conflict resolution via diagnostic fragment fingerprinting, and fragment-confirmed AUC quantification into a single reproducible workflow. The isobaric conflict-resolution step represents the primary algorithmic contribution. Competing assignments within a chromatographic feature are evaluated using a discriminative score constructed from specificity-weighted fragment intensity, effective distinct fragment support, fragment mass accuracy, chromatographic coherence, and calibrated precursor mass likelihood. Assignments are further validated by target-decoy competition with charge-aware decoy fragments and are reported only when they satisfy the fragment-evidence requirements, defeat their corresponding decoy, and meet the specified q-value threshold. Features lacking discriminating evidence are reported as ambiguous rather than assigned. Unlike Skyline-based workflows, which require per-glycan transition curation in GlycoWorkbench and manual peak boundary review, GlycanPRMQuant produces identification and quantitation outputs directly from mzML input with no user intervention, reducing processing time and eliminating a principal source of inter-analyst variability. Quantitative agreement with a manually curated Skyline reference yielded Pearson’s R of 0.992−1.000, with median CVs of 5.08% and 10.72% for bovine fetuin and ribonuclease B glycans across replicate injections.
dlvr.it
November 17, 2026 at 3:58 PM
(Talanta) TiO2-modified paper spray mass spectrometry for selective phospholipid removal in milk and plasma: Publication date: 16 April 2027

Source: Talanta, Volume 315

Author(s): Wei Luo, Mincong Liu, Ming Ma, Bo Chen #Talanta #MassSpecRSS
TiO2-modified paper spray mass spectrometry for selective phospholipid removal in milk and plasma
Publication date: 16 April 2027 Source: Talanta, Volume 315 Author(s): Wei Luo, Mincong Liu, Ming Ma, Bo Chen
dlvr.it
November 18, 2026 at 5:06 PM
(J Proteom) Subcellular proteomics reveals drug-induced compartment-specific protein abundance changes and translocation: Publication date: Available online 11 November 2026

Source: Journal of Proteomics

Author(s): Jianuo Chen, Zhixiang Yan #MassSpecRSS
Subcellular proteomics reveals drug-induced compartment-specific protein abundance changes and translocation
Publication date: Available online 11 November 2026 Source: Journal of Proteomics Author(s): Jianuo Chen, Zhixiang Yan
dlvr.it
November 12, 2026 at 11:03 AM
(JASMS) “Vibe-Coding” Process with AI in Analytical
Chemistry: A Rapid Development Method for Prototyping Instrumentation
and Data Workflows: AbstractModern
analytical instrumentation research is fundamentally built
upon custom software to manage data input/output (I/O) and… (RSS) #MassSpecRSS
“Vibe-Coding” Process with AI in Analytical Chemistry: A Rapid Development Method for Prototyping Instrumentation and Data Workflows
AbstractModern analytical instrumentation research is fundamentally built upon custom software to manage data input/output (I/O) and hardware control. However, development of such software requires extensive experience and expertise in software engineering, limiting the ability of many research groups to develop new instrumental prototypes. The advent of agentic, large-language model (LLM) Artificial Intelligence (AI) software engineering where AI handles all writing, testing, debugging, and execution of code under the direction and validation of the researcher (“Vibe Coding”) provides a mechanism to rapidly bridge this experience gap and give researchers functional, high-level code without necessitating expertise in software development. In this tutorial, we describe a lightweight, four-stage software development lifecycle (SDLC) for agentic coding (prompt engineering and architecture design, iterative agentic debugging, human-in-the-loop validation, and regression testing via simulation) and demonstrate it through the development of a control and analysis software suite for atmospheric pressure Ion Mobility Spectrometry (IMS). This process is easily expanded to any analytical instrumentation in the research laboratory through commonly available Python libraries. As the agent is guided by user prompts, prior knowledge of such libraries is helpful, but not required as modern agents can “plan” a process through both user input and open web search background information. With proper understanding of crafting AI prompts and using them in the SDLC, agentic coding promises to allow rapid prototyping in the research lab at minimal cost.
dlvr.it
November 17, 2026 at 8:04 PM
(JASMS) Revisiting Artifact
Suppression in Electrospray Ionization
Deconvolution: AbstractCharge-state
assignment is a critical step in many workflows
for
intact protein analysis by mass spectrometry. Computational deconvolution
algorithms are increasingly used to automate data… (RSS) #MassSpecRSS
Revisiting Artifact Suppression in Electrospray Ionization Deconvolution
AbstractCharge-state assignment is a critical step in many workflows for intact protein analysis by mass spectrometry. Computational deconvolution algorithms are increasingly used to automate data analysis, but conventional approaches can introduce artifacts. Here, we explore several approaches to removing artifacts by limiting the charge-state assignments for each data point. One approach removes satellite charge states surrounding the local maxima. Another removes harmonics at double the more probable charge assignment. The last two limit either the total number of allowed charge-state assignments or the minimum relative charge-state assignment probability for a given data point. These new features are as effective as the prior SoftMax artifact removal in UniDec, but they enable easier tuning by the user. Although the new set of features introduces additional complexity and an expanded number of parameters, these tools enable users to more precisely reduce artifacts in the deconvolution results.
dlvr.it
November 15, 2026 at 9:05 PM
(RCM) Stable Isotope Analysis in the Mucus of Pellets Represents the Recent Diet of Cormorants: A Noninvasive and Easy‐Sampling Alternative: ABSTRACT

Rationale

The mucus from regurgitated cormorant pellets has been suggested as a noninvasive alternative… #RapidCommunMassSpectrom #MassSpecRSS
Stable Isotope Analysis in the Mucus of Pellets Represents the Recent Diet of Cormorants: A Noninvasive and Easy‐Sampling Alternative
ABSTRACT Rationale The mucus from regurgitated cormorant pellets has been suggested as a noninvasive alternative to blood sampling for stable isotope analysis. However, its suitability, time window, and true representation of mucus remain to be tested. In this study, the pellet mucus of Neotropic cormorants (Nannopterum brasilianum) was analyzed and compared with blood components to infer recently assimilated diets between isotopically distinct estuarine and freshwater environments. Methods Pellet mucus (n = 48), serum (n = 39), and red blood cells (RBCs; n = 39) were analyzed with an isotope ratio mass spectrometer coupled with an elemental analyzer to obtain stable isotopic values of carbon and nitrogen. Statistical tests were applied to compare δ 13C and δ 15N values between sample types. Bayesian isotopic mixing models of blood components and mucus were used to compare estimates of prey source contributions to the inferred diet of cormorants from the Patos Lagoon estuary and the limnetic (Taim Ecological Station) environments in southern Brazil. Results Mucus δ 13C values differed markedly according to the environment sampled. In the estuarine environment, the δ 13C values were like those in serum and RBCs, whereas in the limnetic environment, the δ 13C values in mucus differed from those in blood components. The δ 15N values of mucus differed significantly from those of blood, regardless of the habitat. In the mixing models, there was a continuum of variation in the assimilated proportions of prey, from RBCs to serum and mucus, indicating that mucus might be more like serum and potentially have rapid turnover. Conclusions Stable isotope values of pellet mucus reflected differences in food sources assimilated by cormorants in isotopically distinct environments and may represent a shorter time window than blood components for an assimilated diet. Therefore, it may be useful for indicating recent diet changes because of its fast turnover rate, which is suitable for long-term population monitoring changes in the environment.
dlvr.it
November 17, 2026 at 1:05 PM
(A Chem) Pointless 2.0: A Fast Compositional Modelling Framework to Predict the Isotope Distribution for Average Biomolecules with a Convolution Operator for Modification Handling: AbstractAccurate prediction of isotope distributions is essential for high-resolution mass spectrometry… #MassSpecRSS
Pointless 2.0: A Fast Compositional Modelling Framework to Predict the Isotope Distribution for Average Biomolecules with a Convolution Operator for Modification Handling
AbstractAccurate prediction of isotope distributions is essential for high-resolution mass spectrometry (MS) analysis of biomolecules. We present Pointless 2.0, an updated and unified framework extending our previous Pointless4DNA and Pointless4Peptides models. Pointless 2.0 overcomes key limitations of earlier implementations by introducing a data transformation that enables the use of simple linear models in place of more complex statistical approaches, substantially improving computational efficiency and addressing statistical drawbacks without compromising accuracy. In contrast to prior versions, the framework includes dedicated models for predicting isotope distributions from experimentally measured average mass, in addition to the traditional monoisotopic mass−based approach. Benchmarking against earlier models demonstrates comparable predictive performance while achieving substantial reductions in computational time. Pointless 2.0 further introduces a convolution-based strategy, called IsoSwap, to account for sulphur contributions and post-translational modifications in peptides and oligonucleotides. This modular convolution framework eliminates the need for separate sulphur-specific peptide models and enables flexible post hoc adjustment of isotope distributions. Finally, we present a method to reconstruct monoisotopic and centroid masses from predicted isotope probabilities and experimentally observed average mass, thereby removing dependence on directly observable monoisotopic peaks. The framework further offers an optional intensity-weighted mass-drift correction that estimates and removes a constant calibration offset between predicted and observed isotope masses, validated on experimental DNA spectra spanning seven charge states. Collectively, Pointless 2.0 provides a unified, extensible, and computationally efficient platform for isotope distribution modelling in mass spectrometry. Pointless 2.0 is available at https://github.com/VilenneFrederique/pointless.
dlvr.it
November 15, 2026 at 5:02 AM
(J Chrom A) Quantitative analysis of polar degradation products of nitrogen mustards by alkylchloroformate derivatization and Liquid chromatography-tandem mass spectrometry: Publication date: Available online 17 November 2026

Source: Journal of Chromatography A

Author(s):… #JChrom #MassSpecRSS
Quantitative analysis of polar degradation products of nitrogen mustards by alkylchloroformate derivatization and Liquid chromatography-tandem mass spectrometry
Publication date: Available online 17 November 2026 Source: Journal of Chromatography A Author(s): Rama Krishna Maloth, Nagaraju Maddala, Satya Sri Dharmika Kanakala, Sai Krishna Ganji, Swarajya Lakshmi Vattem Venkata, Vijayasarathi Upadhyayula
dlvr.it
November 18, 2026 at 3:07 AM
(MS Reviews) The Role of Top‐Down Proteomics in Mass Spectrometry Imaging: ABSTRACT

In this Top-Down Proteomics special issue article, we focus on the integration of top-down proteomics in mass spectrometry imaging (MSI). MSI enables the label-free, untargeted,… #MassSpectromRev #MassSpecRSS
The Role of Top‐Down Proteomics in Mass Spectrometry Imaging
ABSTRACT In this Top-Down Proteomics special issue article, we focus on the integration of top-down proteomics in mass spectrometry imaging (MSI). MSI enables the label-free, untargeted, visualization of biomolecules in thin tissue sections. MSI has been widely applied for determining the spatial distributions of small molecules (e.g., metabolites, lipids) and proteins. In the case of proteins, imaging workflows that exploit on-tissue digestion and subsequent analysis of proteolytic peptides (i.e., bottom-up proteomics) are well-established, whereas those that involve analysis of intact proteins are less common. Often, imaging of intact proteins is accompanied by separate bottom-up analysis to identify the protein(s). Rarer still are workflows which combine MSI and top-down proteomics. Top-down proteomics—the analysis of intact proteins by mass spectrometry—allows the identification of unknown proteins and provides information on sequence variants, protein isoforms and posttranslational modifications. It may be conducted under denaturing conditions, where the proteins are intact but unfolded, or under native-like conditions, where solution-phase noncovalent interactions are retained in the gas-phase and proteins remain folded. The latter can provide information on tertiary and quaternary structure, and ligand binding. Top-down proteomics therefore has the potential to provide a comprehensive overview of the proteoform landscape and a more complete picture of the underlying biology. In this article, we provide a brief history of protein MSI together with a more detailed examination of techniques with capabilities for intact protein MSI and associated top-down proteomics, including matrix assisted laser desorption/ionization (MALDI), desorption electrospray ionization (DESI), matrix assisted laser desorption electrospray ionization (MALDESI), laser ablation electrospray ionization (LAESI), liquid extraction surface analysis (LESA), continuous-flow solvent sampling (Flowprobe) and nanospray desorption electrospray ionization (nano-DESI). We discuss the relative merits of the various techniques and provide examples of their application to biological questions.
dlvr.it
November 16, 2026 at 9:01 AM
(JASMS) Multi-Attribute Method
Development and Validation
for Synthetic Peptide Impurity Monitoring toward GMP Release Testing: AbstractSynthetic peptide therapeutics exhibit highly heterogeneous
impurity
profiles containing numerous structural and sequence-related species
that… (RSS) #MassSpecRSS
Multi-Attribute Method Development and Validation for Synthetic Peptide Impurity Monitoring toward GMP Release Testing
AbstractSynthetic peptide therapeutics exhibit highly heterogeneous impurity profiles containing numerous structural and sequence-related species that require stringent analytical control to ensure safety, efficacy, and manufacturing consistency. Conventional UV-based release methods and two-tier LC-UV/LC-MS workflows suffer from coelution ambiguities and cross-method inconsistencies, complicating impurity identification and quantitation. The multi-attribute method (MAM) comprises amino-acid-level impurity characterization, targeted quantitation of product quality attributes, and new peak detection (NPD) as a differential analysis against a reference standard to detect the presence, absence, or change in abundance of any species. Here, we present a multi-attribute method (MAM)-based approach specifically for synthetic peptide impurity monitoring, combining both targeted quantitation of specified impurities and new peak detection (NPD) for unspecified impurities within a single LC-MS workflow that was developed and validated for GMP release testing for a synthetic therapeutic peptide. The MAM workflow leveraged extracted ion chromatograms for specified impurity assignment and quantitation, while non-targeted MS processing enabled NPD-based detection of unspecified impurities exceeding method reporting thresholds. Development mode validation demonstrated satisfactory analytical performance across sensitivity, accuracy, precision, and specificity. Key technical considerations overcome in this workflow include reliable LC-MS discrimination of near-isobaric impurities and optimization of charge-state and isotope peak selection. By consolidating targeted and non-targeted impurity monitoring into a single workflow, this approach eliminates the cross-method inconsistencies inherent to conventional two-tier methods while improving analytical efficiency and specificity through orthogonal retention time and accurate mass discrimination. The workflow was demonstrated on a single synthetic peptide drug substance, with potential applicability to other synthetic modalities yet to be evaluated.
dlvr.it
November 14, 2026 at 11:10 PM
(JASMS) Radiative Cooling
Limits Collisional Heating of Large
Ions: AbstractActivation
of ions inside a mass spectrometer to induce
dissociation
or conformational changes can be a powerful way to investigate their
structure. Although the most common way to activate ions in… (RSS) #MassSpecRSS
Radiative Cooling Limits Collisional Heating of Large Ions
AbstractActivation of ions inside a mass spectrometer to induce dissociation or conformational changes can be a powerful way to investigate their structure. Although the most common way to activate ions in contemporary instruments is by collisions with a neutral buffer gas, ions also constantly exchange photons with the ambient radiation field of the instrument. In blackbody infrared radiative dissociation (BIRD) experiments performed in Fourier-transform ion cyclotron resonance or ion trap instruments at low pressure, radiative energy exchange alone can be sufficient to dissociate or unfold ions on the upper-millisecond to several-minute timescale, depending on the thermochemical barrier and radiation temperature. Collisional activation, as implemented in most commercial platforms, typically occurs on the microsecond- to few-millisecond timescale, a roughly thousandfold shorter kinetic window than in BIRD experiments. Radiative energy exchange effects on collisional heating and cooling for large biomolecular ions in these experiments are poorly understood, and computing radiative energy exchange rates for ions >∼1 MDa has been intractable due to the enormous density of states of these ions. Here, we introduce an algorithm for computing radiative energy exchange rates for large ions as a function of ion mass, composition, and initial vibrational temperature. Scaling of radiative emission rates with ion size and vibrational temperature, and the competition between radiative cooling and collisional heating, are studied by incorporating results from this algorithm into the IonSPA software. Implications for thermochemical CID/CIU barrier determination for large ions and practical limitations for collisional heating of multi-MDa- to GDa-sized ions in charge detection mass spectrometry are also discussed.
dlvr.it
November 15, 2026 at 8:04 PM
(TrAC) Mass spectrometry-based spatial multiple omics fusion for metabolic-immune network analysis: Publication date: Available online 17 November 2026

Source: TrAC Trends in Analytical Chemistry

Author(s): Chao Zhao, Tianyou Cao, Ling Guo, Zhuo Leng, Chihua Li, Dongwen Wang,… #TrAC #MassSpecRSS
Mass spectrometry-based spatial multiple omics fusion for metabolic-immune network analysis
Publication date: Available online 17 November 2026 Source: TrAC Trends in Analytical Chemistry Author(s): Chao Zhao, Tianyou Cao, Ling Guo, Zhuo Leng, Chihua Li, Dongwen Wang, Yihong Zhong, Wenhao Ju, Bin Yan, Zhi Tang, Zhiyi Yang, Yixuan Luo, Jie Hong, Jiyang Dong, Qian Luo
dlvr.it
November 18, 2026 at 2:13 PM
(IJMS) Spatial Metabolomics of Neuroactive Molecules for Neuroscience Research –Challenges, Advances and Outlook: Publication date: Available online 12 November 2026

Source: International Journal of Mass Spectrometry

Author(s): Xin Ma #ijms #MassSpecRSS
Spatial Metabolomics of Neuroactive Molecules for Neuroscience Research –Challenges, Advances and Outlook
Publication date: Available online 12 November 2026 Source: International Journal of Mass Spectrometry Author(s): Xin Ma
dlvr.it
November 14, 2026 at 1:01 AM
(J Chrom B) Development of an integrated method for esterase activity analysis and protein identification by combining nondenaturing two-dimensional electrophoresis, fluorescent activity detection, and tandem mass spectrometry: Publication date: Available online 13 November… #JChrom #MassSpecRSS
Development of an integrated method for esterase activity analysis and protein identification by combining nondenaturing two-dimensional electrophoresis, fluorescent activity detection, and tandem mass spectrometry
Publication date: Available online 13 November 2026 Source: Journal of Chromatography B Author(s): Youji Shimazaki, Koharu Watabe
dlvr.it
November 15, 2026 at 4:03 AM
(JASMS) Modulating Interfacial Fluid Dynamics for Enhanced
Proteoform Analysis Using Nano-DESI Mass Spectrometry: AbstractProteoform imaging
mass spectrometry (PiMS) using nano-DESI MS
enables label-free detection of thousands of intact proteoforms from
biological tissue sections… (RSS) #MassSpecRSS
Modulating Interfacial Fluid Dynamics for Enhanced Proteoform Analysis Using Nano-DESI Mass Spectrometry
AbstractProteoform imaging mass spectrometry (PiMS) using nano-DESI MS enables label-free detection of thousands of intact proteoforms from biological tissue sections and single cells. However, proteome coverage using this approach is limited by the liquid extraction process at the solvent–tissue interface. Here, we demonstrate a simple approach using tailored primary capillary probe size and geometry to enhance proteoform detection. Intriguingly, we found that the enhancement factor strongly depends on the molecular weight and subcellular localization of the proteoforms. We rationalized these observations by dissecting the theory of interfacial fluid dynamics within the nano-DESI liquid bridge. These principles were further leveraged to achieve proteoform detection in surface-immobilized single cells with enhanced sensitivity and throughput.
dlvr.it
November 14, 2026 at 10:05 PM
(RCM) EncNovo: De Novo Peptide Sequencing With an Encoder‐Only Architectures: ABSTRACT

Rationale

De novo peptide sequencing enables interpretation of tandem mass spectrometry (MS/MS) data without relying on sequence databases and is valuable for… #RapidCommunMassSpectrom #MassSpecRSS
EncNovo: De Novo Peptide Sequencing With an Encoder‐Only Architectures
ABSTRACT Rationale De novo peptide sequencing enables interpretation of tandem mass spectrometry (MS/MS) data without relying on sequence databases and is valuable for analyzing proteins from unknown species. However, existing Transformer-based approaches may not fully exploit interactions among precursor information, spectral features, and sequence prediction tokens, potentially limiting sequencing performance. Methods We developed EncNovo, a nonautoregressive de novo peptide sequencing model based on a BERT-inspired encoder-only Transformer architecture. Precursor attributes, spectral peaks, and sequence prediction tokens are jointly encoded within a unified encoder, enabling continuous interaction among the three throughout the encoding process. A residual attention mechanism and a peak mass-difference inductive bias were further incorporated into the self-attention framework to encode amino acid residue mass relationships between spectral peaks. Results Experimental results on the nine-species benchmark dataset demonstrate that EncNovo improves peptide recall at 100% coverage by 5.10 and 4.18 percentage points on average compared with Casanovo and RefineNovo, respectively. The model also achieved higher amino acid recall and demonstrated faster convergence during training. Conclusions Experimental results demonstrate that the proposed encoder-only framework, combined with residual attention and a peak mass-difference inductive bias, effectively improves peptide recall and accelerates model convergence. Collectively, these advantages make EncNovo a reliable framework for de novo peptide sequencing in proteomics.
dlvr.it
November 17, 2026 at 12:04 PM
(ChemRxiv) Prediction and Determination of Monolayer Structure in Binary Ligand Mixtures on Gold Nanoparticles: Controlling multi-ligand assembly on nanoparticles (NPs) is critical for developing advanced nanomaterials for sensing, diagnostics, and therapy. Despite the importance of… #MassSpecRSS
Prediction and Determination of Monolayer Structure in Binary Ligand Mixtures on Gold Nanoparticles
Controlling multi-ligand assembly on nanoparticles (NPs) is critical for developing advanced nanomaterials for sensing, diagnostics, and therapy. Despite the importance of designing nanomaterials with tailored interfaces, it remains poorly understood how the physical and chemical driving forces will influence monolayer morphology for a variety of chemically functional ligand mixtures. In particular, terminal carboxyl and amino moieties offer diverse functionalization pathways. We systematically investigate carboxyl- and methyl-terminated alkanethiols (-COOH/-CH3) and amine- and methyl-terminated alkanethiols (-NH2/-CH3). Both binary monolayer systems included chain length mismatches ranging from 0 to 9 methylene units. We extended a quantitative framework to probe and predict mixed-ligand monolayer self-assembly by integrating matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS) experiments with configurational bias Monte Carlo (CBMC) simulations. Our results revealed that monolayer morphology is significantly impacted by the chain length difference between the chemically distinct mixtures of alkanethiols with either the mercaptocarboxylic acid or amine-functional ligands; both monolayer systems transition from randomly-mixed to phase-separated Janus-like domains as chain length difference increases. The structural asymmetry observed in the phase-separated binary monolayers offers an advantageous and programmable dual purpose platform where hydrophobic domains may impart stability while the functional domains enable targeted binding. This work provides additional insight into the tailored synthesis of multifunctional monolayer-protected ultrasmall nanoparticles for a variety of high-impact applications.
dlvr.it
November 18, 2026 at 12:04 PM
(BioRxiv All) MetaboRx: R Shiny application for quality assessment and preprocessing of mass spectrometry-based metabolomics data: Introduction Metabolomics datasets offer deep insights into biological systems, yet the multi-step analytical workflow, from sample preparation… #BioRxiv #MassSpecRSS
MetaboRx: R Shiny application for quality assessment and preprocessing of mass spectrometry-based metabolomics data
Introduction Metabolomics datasets offer deep insights into biological systems, yet the multi-step analytical workflow, from sample preparation through instrumental analysis, introduces unwanted variation. This variation, including signal drift and batch effects can confound true biological signals. Although rigorous quality control (QC) and data preprocessing are prerequisites for downstream analysis, existing workflows are often fragmented, time-consuming, and inaccessible to non-experts. Objectives To develop a user-friendly software tool for rapid quality assessment and rigorous preprocessing of metabolomics feature tables. Methods MetaboRx is an R Shiny application that integrates orthogonal quality metrics into a single workflow, enabling systematic and transparent evaluation of metabolomics data before and after preprocessing. The application identifies formatting errors and analytically unreliable features and provides flexible preprocessing and visualization options. Results MetaboRx is freely available at https://github.com/ETaylorLab/MetaboRx. Using a semi-targeted LC-MS metabolomics dataset from mouse plasma, perturbed with simulated low-quality data, we demonstrate how MetaboRx facilitates detection of data quality problems, reduces unwanted variation, and prepares data for downstream analysis. Conclusion MetaboRx streamlines metabolomics data quality assessment and preprocessing through an interactive and integrated workflow. The application may improve consistency and reproducibility in metabolomics studies by supporting informed preprocessing decisions and transparent reporting of QC outcomes prior to downstream analysis.
dlvr.it
November 18, 2026 at 10:02 AM
(ChemRxiv) Forced Degradation of Bromantane: Preliminary Characterization of an Oxidative Degradation Product Using Liquid Chromatography and High-Resolution Mass Spectrometry: Bromantane (N-(4-bromophenyl)adamantan-2-amine) is a synthetic adamantane derivative developed as an… #MassSpecRSS
Forced Degradation of Bromantane: Preliminary Characterization of an Oxidative Degradation Product Using Liquid Chromatography and High-Resolution Mass Spectrometry
Bromantane (N-(4-bromophenyl)adamantan-2-amine) is a synthetic adamantane derivative developed as an antiasthenic pharmaceutical agent in Russia. Despite its pharmaceutical applications and relevance to anti-doping analysis, the chemical degradation pathways of bromantane remain insufficiently characterized. This study investigated the forced-degradation behavior of bromantane under acidic, alkaline, thermal, and oxidative conditions using liquid chromatography with ultraviolet detection (LC-UV) and Orbitrap high-resolution mass spectrometry (HRMS). Bromantane remained the predominant chromatographic component following acidic, alkaline, and thermal exposure. In contrast, oxidative exposure resulted in the disappearance of the distinct bromantane UV peak and the appearance of a new chromatographic peak at 20.43 and 20.48 min in two independent preparations. Mass spectrometric analysis revealed a characteristic bromine isotope doublet at nominal m/z 320 and 322. Following retrospective correction of a systematic mass offset, the observed masses were consistent with a proposed neutral molecular formula of C16H18BrNO, corresponding to the addition of one oxygen atom and the loss of two hydrogen atoms relative to bromantane. A nitrone derivative is proposed as a potential structural candidate, although alternative structural isomers cannot be excluded without additional spectroscopic characterization. Substantial variability in integrated peak areas prevented reliable quantification of degradation. These findings provide preliminary insight into the oxidative susceptibility of bromantane and a basis for further degradation-product characterization and analytical method development; no prior forced-degradation study of bromantane was found in the databases searched.
dlvr.it
November 17, 2026 at 2:13 PM
(RCM) Rapid Screening of New Psychoactive Substances in Paper‐Based Prison Correspondence via TEIS‐TQMS: ABSTRACT

Rationale

New psychoactive substances (NPS) are rapidly evolving synthetic compounds designed to mimic controlled drugs while evading legal… #RapidCommunMassSpectrom #MassSpecRSS
Rapid Screening of New Psychoactive Substances in Paper‐Based Prison Correspondence via TEIS‐TQMS
ABSTRACT Rationale New psychoactive substances (NPS) are rapidly evolving synthetic compounds designed to mimic controlled drugs while evading legal regulation. Their increasing presence on impregnated paper materials in correctional and forensic settings creates a need for rapid, selective methods to detect trace quantities in complex matrices, as conventional solvent-based extraction workflows are often too slow for forensic screening. Methods Thermal Extraction Ion Source coupled with Triple Quadrupole Mass Spectrometry (TEIS-TQMS) was evaluated for qualitative analysis of selected NPS spanning different chemical classes. The approach enables direct surface analysis of impregnated materials with minimal sample preparation. Method development included optimization of thermal extraction and ionization parameters, followed by assessment of validation criteria including matrix effects, precision, and limit of detection. Results All analytes were detected with 100% reliability across 10 replicates on every substrate, despite substrate-dependent signal variability (%CV up to 236%). Matrix effects ranged from strong ion suppression (up to 87%) to marked enhancement (up to −2081%), particularly for the synthetic cannabinoid. Limits of detection ranged from 0.05 to 16.13 μg/mL depending on compound, transition, and substrate, confirming the method's suitability for qualitative screening. Conclusions TEIS-TQMS offers a fast, low-sample-handling alternative to conventional methods for detecting NPS on complex surfaces such as impregnated paper. This direct ambient mass spectrometric approach may support the development of more efficient analytical protocols for forensic toxicology and monitoring of emerging psychoactive substances.
dlvr.it
November 17, 2026 at 11:03 AM
(BioRxiv All) Vocabulary recurrence, rather than biological grounding, explains tokenization transfer in protein function prediction.: Sequence-based protein function prediction requires a choice of tokenization. K-mers, the common default, correspond to no biological unit;… #BioRxiv #MassSpecRSS
Vocabulary recurrence, rather than biological grounding, explains tokenization transfer in protein function prediction.
Sequence-based protein function prediction requires a choice of tokenization. K-mers, the common default, correspond to no biological unit; enzymatic digestion offers a principled alternative, since tryptic peptides are the fragments proteases generate and mass spectrometry measures. We asked whether this grounding improves transfer to unseen proteins. Using six Gene Ontology terms and 23,723 UniProt proteins, we compared tryptic peptides, peptide topics (groups of related peptides), 3-mers, and amino- acid composition, with ESM-2 embeddings and homology transfer as reference points. Peptide performance followed vocabulary coverage: 92.2% of peptide tokens in test proteins were never seen in training, whereas almost every 3-mer had been seen. As a result, 38.9% of test proteins contained no peptide the model had seen, and with nothing to work from, the classifier gave all of them the same answer. The remaining 61.1% of proteins were classified almost perfectly with a random forest; however, because of this uncovered fraction, tryptic peptides scored lower overall than 3-mers under all three classifiers tested (macro-F1 0.640 against 0.690). These results suggest that vocabulary recurrence matters more than biological grounding for tokenization transfer.
dlvr.it
November 18, 2026 at 3:58 PM
(JASMS) Strategies for Modifying
a Triple Quadrupole Mass
Spectrometer for Digital Operation in Higher-Order Mathieu Space Stability
Zones: AbstractThe
filtering and analyzing quadrupoles of a commercial triple
quadrupole mass spectrometer were modified for digital operation by… (RSS) #MassSpecRSS
Strategies for Modifying a Triple Quadrupole Mass Spectrometer for Digital Operation in Higher-Order Mathieu Space Stability Zones
AbstractThe filtering and analyzing quadrupoles of a commercial triple quadrupole mass spectrometer were modified for digital operation by replacing the sinusoidal RF drivers with high-precision digital waveform drivers. This modification enables access to higher-order Mathieu-space stability zones (i.e., zones (3,1) and (3,2)) through duty-cycle manipulation of the digital waves. To facilitate this modification, secondary digital waveforms were added to the short rods preceding the analyzing quadrupole to enhance ion transmission. These modifications provide a tractable means to expand the operating parameters and potentially the m/z range of commercial triple quadrupole systems.
dlvr.it
November 13, 2026 at 9:05 PM
(ChemRxiv) Reticular Programming of Gold Nanocluster Electronic States Enables Near-Unity Faradaic Efficiency in Nitrate-to-Ammonia Electrosynthesis: Achieving selective nitrate-to-ammonia electrosynthesis requires more than accelerating nitrate activation: the catalyst must sustain… #MassSpecRSS
Reticular Programming of Gold Nanocluster Electronic States Enables Near-Unity Faradaic Efficiency in Nitrate-to-Ammonia Electrosynthesis
Achieving selective nitrate-to-ammonia electrosynthesis requires more than accelerating nitrate activation: the catalyst must sustain eight-electron reduction while preventing premature intermediate release and competing hydrogen evolution. Yet controlling these competing processes through the molecular architecture surrounding well-defined metal centers remains challenging. Here, we report the first application of gold nanocluster covalent organic frameworks (COFs) to electrocatalytic nitrate-to-ammonia conversion, establishing reticular connectivity as a strategy for programming catalytic electronic environments. Four crystalline frameworks (KIN-1–KIN-4) were constructed from a common pyrazolate-bridged Au3 cluster and structurally differentiated organic linkers. Despite preserving predominantly Au(I) centers, the frameworks exhibit distinct frontier electronic-state distributions, pore architectures, and electrochemical selectivities. The triformylphloroglucinol-linked KIN-2 delivers a near-unity ammonia Faradaic efficiency of 99.5% at −0.70 V versus the reversible hydrogen electrode, with an ammonia productivity of 0.75 mg h-1 cm-2 and only 0.8% Faradaic efficiency toward nitrite. Isotopic labeling verifies nitrate-derived ammonia formation, while in situ attenuated total reflectance surfaceenhanced infrared absorption spectroscopy and differential electrochemical mass spectrometry reveal evolving reactionassociated signatures. Density functional theory identifies preferential *NO hydrogenation through *NHO rather than NOH, with respective uphill free-energy increments of 0.66 and 1.36 eV, alongside unfavorable hydrogen adsorption (ΔGH* = +1.62 eV). These findings demonstrate that reticular construction can differentiate reaction energetics without changing the metal’s formal oxidation state, offering a molecular design principle for directing multielectron electrocatalysis toward desired products.
dlvr.it
November 16, 2026 at 3:07 PM