#Multipathing
🌐 Was bedeutet eigentlich „Fabric“? 🧵

Im Fibre-Channel-SAN ist die Fabric das Verbindungsnetz zwischen Servern und Storage. 

Mehr IT-Wissen: https://www.storitback.de/service/san-fibre-channel-storage-area-network.html

#Storage #SAN #FibreChannel #Multipathing #ITWissen #storitback
November 2, 2026 at 9:03 AM
💾 Was ist eigentlich ein HBA?
💡 Fazit: Ein HBA verbindet Server und Storage.

Weitere Infos: https://www.storitback.de/service/sas.html

#HBA #HostBusAdapter #FibreChannel #SAN #Storage #Multipathing #DualFabric #Virtualisierung #Datacenter #storitback
October 22, 2026 at 9:30 AM
Storage für Proxmox VE – Teil 4: Fibre Channel

Fibre Channel verbindet Proxmox-Hosts über HBAs und ein dediziertes SAN mit zentralem Storage.

Weitere Infos: https://www.storitback.de/service/proxmox-tipps-tricks-konfiguration.html

#ProxmoxVE #FibreChannel #SAN #Multipathing #storitback
October 12, 2026 at 7:31 AM
🚨 EUVD-2026-95798
📊 1.9/10
🏢 illumos

📝 A missing authorization check in the illumos IP management daemon (ipmgmtd) allows a local user to change the persistent IP multipathing (IPMP) configurat...

🔗 https://euvd.enisa.europa.eu/vulnerability/EUVD-2026-95798

#cybersecurity #infosec #cve #euvd
October 9, 2026 at 4:03 PM
✍️ New blog post by Yoshiki Fujiwara(藤原 善基)@AWS Community Builder

Amazon FSx for NetApp ONTAP NVMe/TCP assumes RHEL 9.3: why multipathing fails on Amazon Linux 2023

#aws #linux #networking #cloud
Amazon FSx for NetApp ONTAP NVMe/TCP assumes RHEL 9.3: why multipathing fails on Amazon Linux 2023
Amazon FSx for NetApp ONTAP's NVMe/TCP procedure assumes RHEL 9.3: why multipathing is...
dev.to
September 30, 2026 at 5:44 AM
Amazon FSx for NetApp ONTAP NVMe/TCP assumes RHEL 9.3: why multipathing fails on Amazon Linux 2023
# Amazon FSx for NetApp ONTAP's NVMe/TCP procedure assumes RHEL 9.3: why multipathing is unavailable on Amazon Linux 2023, and how to check before you are billed Followed the AWS procedure and run `cat /sys/module/nvme_core/parameters/multipath` only to find the file isn't there? Moving your target Linux distribution to Amazon Linux 2023 can stop a documented command from working exactly as written. You are reading the procedure correctly, yet your environment alone gives a different result — and tracking the cause down to a kernel build setting takes time. This article is for anyone who got stuck at that point. What this article does and does not cover: it covers how to confirm multipathing is unusable on AL2023, and how to count whether it is actually using the second path. It does not cover performance comparisons or a generalized conclusion for distributions other than AL2023 (details under "What this article does not cover" below). All figures are from a Single-AZ configuration; Multi-AZ is unverified. dev.to series: `FSx for ONTAP Block Protocols, Measured`. ## What was checked Assuming no prior knowledge of FSx for ONTAP, here's what this article is confirming. * **Location** : a single AWS VPC, single AZ * **Client** : one EC2 instance (Amazon Linux 2023) * **Target** : one Amazon FSx for NetApp ONTAP file system (second-generation SINGLE_AZ_2). The HA pair's two controllers hold two paths to one namespace * Path 1: to the `optimized` controller (shortest path) * Path 2: to the `non-optimized` controller. Only when multipathing is available can the host tell that path 2 is a standby _Figure: an FSx for ONTAP HA pair has two paths to one namespace, and **Asymmetric Namespace Access is the mechanism that tells the host which one is the shortest path_* (referred to as multipathing throughout this article). Without this mechanism in the kernel, those two paths don't appear as "one shortest path plus one standby": they appear as two separate devices pointing at the same data.* Item | Role in this article ---|--- VPC / AZ | Single AZ, so both paths to the HA pair's controllers sit on the same network EC2 client | Checks for multipathing and the kernel configuration behind it optimized path | The shortest path as determined by multipathing. Real data is expected to flow here non-optimized path | The failover path. Without multipathing it appears as an ordinary path too AWS's Provisioning NVMe/TCP for Linux includes a step that confirms multipath has come up: the fourth item under "To discover the target NVMe nodes". **It says that a returned`Y` means success** (wording as of 2026-09-17; every reference to that page below was checked on the same day). cat /sys/module/nvme_core/parameters/multipath # Y means success **On the Amazon Linux 2023 AMIs I used, that file did not exist.** The kernel does not have Asymmetric Namespace Access (a mechanism that tells the host which of several paths to the same namespace is the shortest one) in it. The range I checked is the three kernel series returned by `al2023-ami-kernel-default-x86_64`, so I cannot write "AL2023 always behaves this way". Checking takes one command, and a later section gives it. The procedure is written for RHEL 9.3. The same page's "Before you begin" says `Create an EC2 instance running Red Hat Enterprise Linux (RHEL) 9.3`. Immediately after that there is a statement about other distributions. In summary: on AMIs other than RHEL 9.3 some of the utilities may already be present or the install command may differ, but **apart from installing packages, the commands in this section are valid on other EC2 Linux AMIs too** (the original wording is at the end of "Before you begin" on that page). **What this article reports is two counterexamples to that statement.** Neither of them is explained by package installation. Command from the documentation | Result on AL2023 | A packaging problem? ---|---|--- `cat /etc/nvme/hostnqn` | **File does not exist** | No. `nvme-cli` is installed; whether it creates this file differs by distribution `cat /sys/module/nvme_core/parameters/multipath` | **File does not exist** | No. This is a **kernel build option** (`CONFIG_NVME_MULTIPATH`) and a package cannot change it **You can check this before any billing starts.** That is the most practical part of this article, I think. > This is not a claim that "the documentation is wrong". It is a report that **these two do not > fall inside** the stated range (apart from installing packages, valid on other AMIs too). > The state of my feedback to AWS is at the end of this article. Then, after bringing in a kernel that does have multipathing, I found that **the`optimized` / `non-optimized` output of `nvme list-subsys` says "there are two paths", not "two paths are in use".** Whether they are in use has to be counted separately, and there is a trap in choosing which table to count. What this article does not cover. It does not compare performance. The figures here exist to show that two clients agreed under the same conditions, and **they cannot be used for sizing.** What moves the numbers is in a separate article. All figures are from a Single-AZ configuration; Multi-AZ is unverified. > This is one of three, but there is no reading order. The block-protocol measurements are split > by reader. > > | Article | Reader > ---|---|--- > **A** | Session and queue counts | Anyone about to mount > **B** | **Checking whether multipathing is available** (this article) | Anyone who followed the procedure and got stuck > **C** | What moves the numbers | Anyone measuring or citing figures > > None of them assumes the other two. Read only the part you need. ## The environment I measured Item | Value ---|--- File system | Amazon FSx for NetApp ONTAP, second generation SINGLE_AZ_2, 6,144 MBps × 1 HA pair, 4,096 GiB SSD, 200,000 provisioned IOPS Region | ap-northeast-1, single AZ ONTAP | **9.18.1** (the reads and writes in the agreement table). **For the 12 sequential-write points I failed to record the version.** `FileSystemTypeVersion` returned `null` and I tore the environment down before re-reading it from the cluster API. The kernel investigation also spans deployments on other versions. The cross-article version mapping is in the ONTAP version matrix NVMe read cache | **Disabled** (confirmed on both nodes) LUN / namespace | 600 GiB, on a 900 GiB volume Before measuring | **Wrote the full 600 GiB once.** Unwritten blocks on a thin-provisioned volume return zeros, so reading without writing first measures nothing Client | c5n.9xlarge; 50 Gbps network is a guaranteed figure Instrument | VDBENCH 5.04.07 directly, **`iorate=max` (unlimited)**, 512 threads, 60 s warm-up + 300 s measurement Test data / efficiency settings | **Not recorded whether the VDBENCH payload was compressible, or whether volume inline efficiency (`StorageEfficiencyEnabled`) was enabled.** On the file-protocol side, efficiency settings measurably affected figures; whether the same applies to block is unconfirmed **The window is 300 seconds, so the figures in this article include burst. They cannot be cited as a baseline.** > The figures in this article are `iorate=max` saturation points, not operating points. No target > IOPS was given; they are what the system took when everything available was pushed at it. On the > file-protocol side of the same repository, giving a target of 4,400 IOPS produced 4,406 MB/s at > 8.86 ms, while unlimited produced 4,204 MB/s at 121.79 ms. **Unlimited was 5% lower in > throughput and 14 times higher in response time.** > > With 512 threads fixed and no rate limit, response time becomes the identity `512 ÷ IOPS` > (derived 216.6 ms against measured 216.588 ms in a separate run). The figures below can be read > through that identity: 1,277.48 MB/s is about 401 ms, and 131,736.5 IOPS is about > 3.9 ms. **Both are derived values and were not recorded as measurements.** > > For this article's purpose, being a saturation point is not a disadvantage. The figures are > here to show that Rocky and RHEL agreed under the same conditions, and as long as both are > saturated the same way, the agreement test holds. **Those values still cannot be used for > sizing.** ## Behaviour on this AMI **On this AMI the file named at the top does not exist.** Reading the kernel configuration gives `# CONFIG_NVME_MULTIPATH is not set`, and `modinfo nvme_core` has no multipath parameter either. So multipathing is not in the kernel. As a result the two controllers are not merged into one device; they appear as **separate devices pointing at the same namespace UUID** (`/dev/nvme2n1` and `/dev/nvme3n1`). `nvme list-subsys` shows no `optimized` / `non-optimized` either. **The AWS procedure is written for RHEL 9.3, where it is present.** > Please do not generalise this to "multipathing is not available on AL2023". What I observed were the > AMIs that the `al2023-ami-kernel-default-x86_64` SSM parameter returned on 2026-09-12 and > 09-13, and **I did not record the kernel versions.** The template said "record the kernel version > at measurement time" in place of pinning the AMI, and the block phase did not implement that. > That is a gap in my records. > > Checking in your own environment is more reliable, and it is one command. > > > grep -i NVME_MULTIPATH /boot/config-$(uname -r) > **I later widened the observation to three kernel series.** All three returned by `al2023-ami-kernel-default-x86_64` (6.1.186 / 6.12.103 / 6.18.48) gave `# CONFIG_NVME_MULTIPATH is not set`. You can check this before creating a file system, by extracting the config from the kernel package in the repository. It is known before billing starts, so checking in that order is cheaper. To measure multipathing I then brought in another distribution. **The AWS procedure is written for RHEL 9.3, so I put both Rocky Linux 9.7, a rebuild, and RHEL 9.7 itself on the same namespace and compared them.** Workload | RHEL 9.7 | Rocky 9.7 ---|---|--- 1 MiB sequential read | 1,277.48 MB/s | 1,276.60–1,279.22 MB/s 4 KiB random read | 131,736.5 IOPS | 131,550.6 / 131,749.4 IOPS 4 KiB random write | 195,439.8 IOPS | 194,960.6 IOPS **Only the reads agreed in the same state** (within 0.1%). Same minor version, same `nvme-cli` (2.16-1.el9), same cold state. The kernels differ in z-stream (5.14.0-611.55.1 against 611.5.1). For reads, there is now one piece of grounds for reading a rebuild's figure as the figure for the product itself. > Both write workloads had the Rocky side measured warm, so the states are not aligned. Counting > the 0.3% difference on 4 KiB random write as "agreement" was my error, and **the note in that same > table contradicted my own conclusion** (corrected 2026-09-20). For that shape I can say neither > that it holds nor that it does not. > > Sequential write was re-measured later, in the same state, for that shape alone. **It does not > agree (2026-09-17).** On a different file system (second generation, 1,536 MBps, 50,000 provisioned > IOPS), same namespace, same state, same parameters, six runs each. > > Client | Min | Median | Max | Spread > ---|---|---|---|--- > Rocky 9.7 | 842.70 | 1,040.26 | 1,092.50 | 29.6% > RHEL 9.7 | 1,105.75 | 1,112.65 | 1,129.30 | 2.1% > > Units MB/s (1 MiB sequential write, 8 threads, `o_direct`, 120-second window). These 12 > points were taken under conditions that differ from the environment described at the top: a > different file system (second generation, 1,536 MBps, 50,000 provisioned IOPS), 8 threads rather > than 512, and 120 seconds rather than 300. The `512 ÷ IOPS` reading given at the top cannot be > applied to these 12 points. **RHEL's minimum is above Rocky's maximum** : six against six, with no > overlap in range. RHEL's median is 7.0% above Rocky's, and the asymmetry in spread is larger than > the difference in medians. > > So "a rebuild's figure can be read as the figure for the product itself" is limited to the > reads. When citing a sequential-write figure, say which of the two it was measured on. > 4 KiB random write was not re-measured in the same state, so for that shape I can say neither > that it holds nor that it does not. **I cannot state a cause.** The only difference on record is > the kernel z-stream, and I did not vary it on its own. During the runs the file system side was at > 72–81% disk throughput, 16–19% IOPS and 31–38% network, none of them saturated (so this is not a > case of the two meeting at a ceiling). For these 12 points I failed to record the ONTAP version. > `FileSystemTypeVersion` returned `null` and I tore the environment down before re-reading it from > the cluster API. ### `iopolicy` on a kernel with multipathing, and the value the procedure states **This is the third counterexample.** `iopolicy` (Linux's multipath setting that decides how I/O is distributed across multiple paths to an NVMe device: `round-robin` cycles through them, `queue-depth` sends to whichever has the shortest queue) is what step 5 of the same procedure says to confirm as `round-robin` (and the example `nvme list-subsys` output at step 7 also shows `iopolicy=round-robin`). | Value ---|--- Value the documentation says to confirm | `round-robin` **Measured on Rocky Linux 9.7 / RHEL 9.7** | **`queue-depth`** What set it | the udev rule `71-nvmf-netapp.rules` shipped by `nvme-cli` (2.16-1.el9) **The kernel default is`numa`, neither `round-robin` nor `queue-depth`.** It was `queue-depth` in this environment because the NetApp-oriented udev rule bundled with the `nvme-cli` package set it. Following the confirmation step returns a value other than the expected one. I measured the effect on performance. It is negligible: switching policy mid-run produced no step change, and the difference was 0.5%. The figures and the method are in a separate article (C). So this is not a story about `round-robin` being required for speed. **The only part worth reporting is that the confirmation step returns a value that differs from the documentation.** > This can change with the `nvme-cli` version. What I observed here is one version, 2.16-1.el9, > and **I did not confirm whether other versions ship the same udev rule.** ## How to check whether multipathing is using the second path This section was added afterwards. It became necessary in order to do the analysis above, and it is also the reason I once published a wrong conclusion. `nvme list-subsys` shows the two controllers as `optimized` / `non-optimized`, and prints `iopolicy` as well. **That is a display of "there are two paths", not of "two paths are in use".** At first I varied `iopolicy` three ways, compared total throughput, saw that only `queue-depth` was faster, and wrote that "only `queue-depth` uses the second path". **That was wrong.** I had not counted bytes per path. A client-side total that does not increase is consistent with two different facts: "the second path is not being used", and "it is being used but the ceiling is nearer than the path". ### Bytes per path can be read from two places On the ONTAP side they can be read from a counter table. **There is a trap here.** Table | Result in this configuration ---|--- `nvmf_lif` | **Zero rows.** Still empty after writing 600 GiB over NVMe/TCP `lif` | Reports **0 bytes** for the LIF in question. It does not count NVMe-oF **`nvmf_tcp_port`** | **Has the real data.** `read_data` / `write_data` / `total_ops` per LIF "The table exists but has no rows" and "this version does not have that table" add up to the same appearance. Return 0 and move on, and **you reach the correct conclusion, "the second path saw 0 bytes", for the wrong reason.** It can also be counted on the client side. NVMe/TCP controllers have different destination addresses, so aggregating established sockets by destination separates the paths. That is a second source, independent of the ONTAP side. ss -tin state established | awk '/:4420/{...}' # sum bytes_sent / bytes_received per destination ### Counted properly, the second path was not running I ran four workloads under `queue-depth` and took before/after differences. Path | Read bytes | Write bytes | Total ops ---|---|---|--- optimized | +about 1,012 GiB | +about 730 GiB | 641,908 → 120,008,866 **non-optimized** | **±0** | **±0** | **4 → 4** **Neither reads nor writes went to the second path.** The ONTAP side and the client side agreed, and it was the same on Rocky and on RHEL (the second path's increment across all workloads was about 20 KB). Further, switching `iopolicy` within a single run produces no step change. With a sequential read running I changed `queue-depth` → `numa` → `queue-depth`, and the values sampled at one-second intervals stayed inside the same 1,150–1,400 MB/s range both before and after each switch. ## Summary * **All three kernel series returned by`al2023-ami-kernel-default-x86_64` (6.1.186 / 6.12.103 / 6.18.48) had `CONFIG_NVME_MULTIPATH` unset.** Measuring multipathing requires a different distribution. **Asking AWS why AL2023 is excluded from the procedure (reply 2026-09-21) surfaced a likely reason:** `nvme connect-all` establishes both paths and auto-discovers the alternate LIF even when only one is given, but without `CONFIG_NVME_MULTIPATH` the kernel never merges them into one namespace device. The procedure's later steps assume that merge already happened, so proceeding unmerged leaves the other path writable against the same namespace with no multipath software mediating it: **a data-corruption risk** * **You can check before creating a file system.** Extract the config from the kernel package in the repository and you know before billing starts. On a running instance it is the one command `grep -i NVME_MULTIPATH /boot/config-$(uname -r)` * **Rocky Linux 9.7's figures can be read as RHEL 9.7's figures, but only for the reads.** On the same namespace in the same state they agreed within 0.1%. Both write workloads had the Rocky side measured warm, so the states are not aligned. Counting the 0.3% difference on 4 KiB random write as agreement was my error, and for that shape I can say neither that it holds nor that it does not (corrected 2026-09-20). Sequential write does not agree: re-measured later in the same state, six runs each, RHEL's median was 7.0% higher and RHEL's minimum was above Rocky's maximum (spread 29.6% for Rocky against 2.1% for RHEL). When citing, say which of the two it was measured on * **`optimized` / `non-optimized` in `nvme list-subsys` is a display of path existence.** For whether they are in use, count with the `nvmf_tcp_port` counters. `nvmf_lif` returns no rows, and `lif` does not count NVMe-oF * **In this configuration, not one byte went to the second path even under`queue-depth`.** Two places agreed (the ONTAP-side counters and the client-side sockets), and it was the same on Rocky and on RHEL ## AWS documentation notes and support inquiries This article touches three places in the documentation. All three were submitted on 2026-09-17. The source for all of them is Provisioning NVMe/TCP for Linux. Remark | State ---|--- Against "apart from installing packages, valid on other EC2 Linux AMIs too": `cat /etc/nvme/hostnqn` finds no file on AL2023 | Submitted (2026-09-17). **Reproduced in the same environment, confirming the wording doesn't hold as-is for the AL2023 environment checked.** The two proposed fixes (scoping the wording, adding a generation step) have been shared as an improvement request. Adoption, content, and timing are unconfirmed Against the same statement: `cat /sys/module/nvme_core/parameters/multipath` finds no file on AL2023 (kernel build option) | Submitted (2026-09-17). **The observation was confirmed and filed as documentation feedback. Fix timing undecided.** A follow-up question ("why is AL2023 excluded from scope?") also got a technical explanation: proceeding with the paths unmerged leaves the other path writable against the same namespace with no multipath software mediating it, a **data-corruption risk** , so the exclusion has a technical rationale Step 5 directs confirming that `iopolicy` is `round-robin`, but the measurement on Rocky 9.7 / RHEL 9.7 is `queue-depth`. `nvme-cli`'s version boundary is **2.11 - > 2.12** (see below) | Submitted (2026-09-17). **On 2026-09-30 it was acknowledged that a note is needed stating whether`iopolicy` resolves to `round-robin` or `queue-depth` depends on the environment, and this was fed to the responsible team** (with a note that NetApp's own published documentation carries the same point). The content and timing of any change are not disclosed in advance, so they are unconfirmed The form I submitted was this. Verbatim quotation (which line of which step), reproduction steps, expected and measured values, and the range I confirmed across three kernel series, written as such. **Not generalising to "multipathing is not available on AL2023"** is the same in the feedback: the observation is limited to the three series returned by `al2023-ami-kernel-default-x86_64`. For the second one I also included the control under which the procedure does hold (on a kernel with `CONFIG_NVME_MULTIPATH=y`, `Y` is returned). It is not a report that the procedure itself is wrong. The third is not submitted as a performance problem. **The difference between policies is 0.5% in this configuration, and the report is the single point that the confirmation step returns a value differing from the documentation.** The third changed shape before submission, after I looked at the package side. Reading `71-nvmf-netapp.rules` out of four builds of the public `nvme-cli` package (the SRPMs for 2.11 / 2.13 / 2.16, plus the installed 2.16-1.el9) showed that 2.11 has `round-robin` and 2.13 changed it to `queue-depth` (confirmed 2026-09-17). At that point 2.12 had not been examined, so the boundary could only be written as "somewhere between 2.11 and 2.13". Submission status across the three block-protocol articles and S3 Burst Part 2 is collected in AWS documentation notes and inquiries across the block-protocol articles. A pointer to the upstream v2.11 and v2.12 sources followed, showing the boundary is v2.12. Fetching and checking that commit (2026-09-19, `71-nvmf-netapp.rules.in`) confirmed that `queue-depth` was already in place as of v2.12. **So the version boundary is settled at 2.11 -> 2.12** (the original "somewhere between 2.11 and 2.13" narrowed to 2.12, from both that pointer and my own re-check). This is agreed to be a version drift rather than an error in the documentation. On 2026-09-30, it was acknowledged for this point that a note is needed stating that whether `iopolicy` resolves to `round-robin` or `queue-depth` depends on the environment, and it was fed to the responsible team. NetApp's NVMe-oF procedure for RHEL 9.x carries the same point (from RHEL 9.7 the default is `queue-depth`; on 9.6 `round-robin` is the default with `queue-depth` selectable), consistent with this understanding. **The content and timing of any change are not disclosed in advance, so its reflection in the documentation is unconfirmed.** ## Primary record of the figures The primary record of the figures and their conditions is in the protocol measurement results, and the reproduction steps are in the block measurement runbook. What is unconfirmed is written as unconfirmed there, so **please do not drop that when citing.** How to check whether multipathing is available, counter-table traps, and `iopolicy` version differences are collected in Considerations when measuring FSx for ONTAP's block protocols.
dev.to
September 30, 2026 at 5:52 AM
They got dizzy! Their heads hurt. They had to learn about multipathing!

You monsters! Us! Us monsters!
September 25, 2026 at 2:29 PM
Most iSCSI pain in Proxmox is multipathing, not the target. Add a second NIC with no MPIO config and you get failover on paper plus a hung datastore in production. Check path state before blaming the filesystem.
September 19, 2026 at 6:02 PM
A link will fail. But the network can’t. From LOS and cellular to SATCOM and multipath, modern drone platforms need connectivity that adapts as fast as the mission does. Learn how #ZeroTier helps keep UAVs connected through disruption today, while preparing them for the PQC requirements coming up.
The Network Behind the Mission: Why Multipathing Matters for All Drones
Multipath networking helps drones stay connected as they move between line-of-sight (LOS) Wi-Fi, cellular, and SATCOM links.
www.zerotier.com
September 15, 2026 at 8:18 PM
NVMe over Fabrics is where network storage stops feeling like the network: sub-100us reads and the fabric behaves like a PCIe bus. Unforgiving, though - jumbo frames, no drops, multipathing done right. Field notes: https://netapp-blackbox.pages.dev/reference/nvme-of.html #NetApp #Storage
September 3, 2026 at 8:43 PM
⛓️ The protocol supports native multipathing and out-of-order delivery to reduce network friction in large AI training jobs.
August 26, 2026 at 7:07 AM
New guide: SnapMirror Active Sync & SM-BC.

Zero RPO/RTO business continuity: ONTAP Mediator quorum, uniform vs non-uniform SAN multipathing, auto-failover, and CLI setup.

https://netapp-blackbox.pages.dev/reference/snapmirror-active-sync.html

#NetApp #ONTAP
August 24, 2026 at 8:55 PM
New guide: ONTAP SAN Configuration & Multipathing.

Covers ALUA path states, Selective LUN Map (SLM), Linux DM-Multipath, ESXi NMP/PSP tuning, and NVMe-oF ANA namespaces.

Guide: https://netapp-blackbox.pages.dev/reference/san-multipathing

#NetApp #ONTAP #StorageAdmin #SAN
August 24, 2026 at 2:37 PM
I'm just hoping with the change to Fedora that multipathing will work. 🥲
August 20, 2026 at 4:55 PM
NFS 3 vs. NFS 4.1 for VMware ESXi: A Decision and Migration Guide

NFS 3 and NFS 4.1 are both supported storage protocols for VMware ESXi, but they differ significantly in architecture, security, multipathing, and operational capabilities. This guide compares NFS 3 and NFS 4.1 to help VMware…
NFS 3 vs. NFS 4.1 for VMware ESXi: A Decision and Migration Guide
NFS 3 and NFS 4.1 are both supported storage protocols for VMware ESXi, but they differ significantly in architecture, security, multipathing, and operational capabilities. This guide compares NFS 3 and NFS 4.1 to help VMware administrators choose the right protocol based on performance, availability, scalability, and infrastructure requirements. The guide also explains the key considerations for migrating existing VMware datastores from NFS 3 to NFS 4.1.
vmorecloud.com
August 18, 2026 at 7:22 AM
like, i always love playing crafters, and the artifabrian scratches that itch beautifully, and it’s one way to play my typical smartypants support character, with plenty of room to grow into a very well rounded supportive character by multipathing
March 13, 2026 at 2:01 PM
Updated to #xenserver 9 today and all my SCSI storage repositories were broken (both iSCSI and FibreChannel). It turns out that if you have a USB memory stick plugged in, it kills multipathing on the whole system.

# multipath -ll
sde: broken device without vendor ID
# multipath -v9
[snip]
596 […]
Original post on justfollow.me.uk
justfollow.me.uk
July 22, 2026 at 10:22 AM
New blog posting, Linux multipathing - http://tinyurl.com/25nwry9
March 20, 2025 at 12:25 PM
Miscellaneous stuff I hadn't posted here yet
December 30, 2025 at 3:52 PM
Oh fun, being able to hear a speaker in an auditorium is strongly based off of multipathing/reverb (analogous to some of the basin amplification effects in seismic waves), letting the inverse square law for diminishing sound intensity not apply (to a degree).
Reverberation
hyperphysics.phy-astr.gsu.edu
June 17, 2026 at 5:45 PM
*scans GPS accuracy stuff reddit (a mistake)*

Does anyone that actually *works* in geodesy every correct these people? Anyone who's had like one grad class on it?

Lots of stuff about "secret military encoding," not much on multipathing, atmospheric conditions, etc.
March 29, 2026 at 1:30 AM
How This Cisco Nexus & UCS Data Center Design Eliminates STP – But Opens 3 Critical Security Gaps You Must Fix Now + Video

Introduction: Modern data centers rely on FabricPath, vPC, and FCoE to eliminate Spanning Tree Protocol and maximize link utilization. While these technologies boost…
How This Cisco Nexus & UCS Data Center Design Eliminates STP – But Opens 3 Critical Security Gaps You Must Fix Now + Video
Introduction: Modern data centers rely on FabricPath, vPC, and FCoE to eliminate Spanning Tree Protocol and maximize link utilization. While these technologies boost resilience and throughput, they introduce unique attack surfaces—from unauthorized FCoE injection to OTV encapsulation abuse—that traditional security tools miss. Learning Objectives: Configure and verify FabricPath multipathing, vPC active-active links, and FCoE convergence on Cisco Nexus switches. Implement security mitigations against VLAN hopping, FCoE spoofing, and OTV traffic leakage.
undercodetesting.com
June 11, 2026 at 1:41 PM
In a tight environment with lots of press and microphones and radios and streaming and everything else, you have a VERY noisy EM environment. Introduce multipathing interference from your aerial compatriots and this very quickly becomes a shitshow. That's the first reason why you don't wanna.
July 21, 2024 at 2:15 AM
Obvious start would be to use OFDM with the modulated signal to provide resilience to multipathing in urban and mountainous regions, without much of a trade-off for large flat areas. Where it goes beyond that depends on the options for encoding and how well you can divide up bandwidth.
December 14, 2025 at 6:27 AM
My board doesn't have the I/O necessary to add even the jankiest 10g adapters, but has 4x2.5g ports. So ofc I'm gonna try to find out what I can do to make the best of what I have?? Currently looking into iscsi multipathing and SMB multichannel...
December 5, 2024 at 12:53 AM