#PowerSystem
Critical CVSS-9.0 flaws in PowerSYSTEM Center let regular users access admin resources or run unauthorized SQL. #SecurityNews #Vulnerability #CISA #PowerSYSTEM #OTsecurity https://thedailytechfeed.com/critical-powersystem-center-flaws-expose-industrial-systems-to-9-0-rated-risks/
November 9, 2026 at 10:59 AM
CISA Warns Two Critical 9.0 Flaws in PowerSYSTEM Center Allow Unauthorized Access and SQL Injection
CISA Warns Two Critical 9.0 Flaws in PowerSYSTEM Center Allow Unauthorized Access and SQL Injection
CISA warned that two critical PowerSYSTEM Center flaws (CVSS 9.0) could let authenticated users access administrator resources or execute unauthorized database commands, affecting energy and manufacturing sectors worldwide. The agency released advisory ICSA-26-307-01 on November 3, 2026. CISA credited Chinmay Patel of Digital Boundary Group and Subnet Solutions with reporting the vulnerabilities. The Canadian vendor has provided upgrade guidance and temporary measures for organizations that cannot immediately update affected systems. The first flaw, CVE-2026-63017, involves incorrect authorization , tracked as CWE-863. A user with limited permissions can access resources normally reserved for administrators. In simple terms, signing in with a basic account does not keep the user within the access limits intended for that account. CISA Warns Critical Flaws in PowerSYSTEM Center The second flaw, CVE-2026-63774, is an SQL injection vulnerability tracked as CWE-89 . Insufficient input checks in the report designer allow an authenticated user to execute unauthorized SQL commands. The disclosed impact concerns database commands, not confirmed operating system code execution. Both CVSS vectors describe low attack complexity, low privileges, and no required user interaction. They specify an adjacent attack vector rather than unrestricted network access. CISA states that these vulnerabilities are not remotely exploitable and that no known public exploitation had been reported when the advisory was released. CVE-2026-63017 affects PowerSYSTEM Center 2020 versions through 5.29.x, PowerSYSTEM Center 2024 versions 6.0.x through 6.2.x, and PowerSYSTEM Center 2026 versions 7.0.x through 7.1.x. CVE-2026-63774 affects the listed 2024 and 2026 ranges. The advisory does not list the 2020 branch as affected by SQL injection. Subnet Solutions recommends PowerSYSTEM Center 2020 Update 30 for affected 2020 installations. Organizations running the 2024 branch should upgrade to PowerSYSTEM Center 2026 Update 1.1. Existing 2026 installations should also update to Update 1.1, according to CISA’s machine-readable advisory. Checking installed versions is therefore essential before planning upgrades. Cybersecurity News previously covered CISA’s OT asset inventory guidance , which explains how accurate device and software records support vulnerability management across industrial environments. For organizations unable to update, Subnet recommends monitoring user activity records and restricting Client Access Server users’ access to browser F12 Developer Tools to reduce authorization-related risk. For the SQL injection issue, the vendor recommends restricting user access to the report designer. These are interim measures, not replacements for the recommended updates. CISA also advises keeping control systems off the public internet, placing them behind firewalls, and separating them from business networks. Where remote access is necessary, organizations should use updated VPNs and assess connected devices. Related secure OT connectivity guidance explains the value of limited exposure and controlled connections. Before applying changes, operators should assess operational impact and risk. Operators should follow internal response procedures for suspected malicious activity and report it to CISA. Give your SOC the alert context to stops incidents quickly. Integrate Threat Intel from 16K SOCs . The post CISA Warns Two Critical 9.0 Flaws in PowerSYSTEM Center Allow Unauthorized Access and SQL Injection appeared first on Cyber Security News .
cybersecuritynews.com
November 9, 2026 at 10:49 AM
CISA Warns Two Critical 9.0 Flaws in PowerSYSTEM Center Allow Unauthorized Access and SQL Injection

cybersecuritynews.com/cisa-warns-c...

#Cybersecurity #LargeScaleImpact #Vulnerability
CISA Warns Two Critical 9.0 Flaws in PowerSYSTEM Center Allow Unauthorized Access and SQL Injection
CISA warned that two critical PowerSYSTEM Center flaws could enable unauthorized administrator access and database command execution.
cybersecuritynews.com
November 9, 2026 at 11:15 AM
November 6, 2026 at 2:07 AM
November 6, 2026 at 2:06 AM
CVE-2026-63017 - Subnet Solutions PowerSYSTEM Center Incorrect Authorization
CVE ID : CVE-2026-63017

Published : Nov. 6, 2026, 12:01 a.m. | 1 hour, 7 minutes ago

Description : Incorrect authorization in PowerSYSTEM Center allows a low-privileged, authenticated user to ac...
CVE-2026-63017 - Subnet Solutions PowerSYSTEM Center Incorrect Authorization
Incorrect authorization in PowerSYSTEM Center allows a low-privileged, authenticated user to access resources normally limited to administrators.
cvefeed.io
November 6, 2026 at 1:30 AM
How Would You Light Up the Apocalypse?
From a small campfire to a fully illuminated survival base, we're working to give players different ways to light up their world.
#theapocalypse #survivalgame #basebuilding #lightingsystem #powersystem #openworldgame #zombiegame #survivalcraft #gamedev #steam
November 4, 2026 at 5:34 AM
CVE-2026-63774 - Subnet Solutions PowerSYSTEM Center SQL Injection
CVE ID : CVE-2026-63774

Published : Nov. 6, 2026, 12:05 a.m. | 1 hour, 3 minutes ago

Description : Insufficient input validation in the PowerSYSTEM Center report designer allows an authenticated user to e...
CVE-2026-63774 - Subnet Solutions PowerSYSTEM Center SQL Injection
Insufficient input validation in the PowerSYSTEM Center report designer allows an authenticated user to execute unauthorized SQL commands.
cvefeed.io
November 6, 2026 at 1:36 AM
🔴 CVE-2026-63774 - Critical (9)

Insufficient input validation in the PowerSYSTEM Center report designer allows an authenticated u...

https://www.thehackerwire.com/vulnerability/CVE-2026-63774/

#infosec #cybersecurity #CVE #vulnerability #security #patchstack
November 6, 2026 at 1:46 AM
Low-privileged users can reach admin-only data and run SQL in grid software PowerSYSTEM Center. Patch now. https://intel.threadlinqs.com/threat/TL-2026-5604?utm_source=bluesky #ThreatIntel #CVE_2026_63017 #CVE_2026_63774 #ICSA2630701
November 9, 2026 at 11:55 PM
ZohoがManageEngine Key Manager Plus、Log360、およびPAM360の11の脆弱性を修正 #Security Online (Nov 6)
securityonline.info/manageengine...
https://securityonline.info/subnet-solutions-powersystem-center-flaws-patched/
securityonline.info
November 9, 2026 at 3:30 AM
Switch Pros SP-9100 8-Switch Panel Power System With Concealed Mounting Hardware #Automation #PowerSystem #Switch #Lighting #Dimmable
Switch Pros SP-9100 8-Switch Panel Power System With Concealed Mounting Hardware
www.amazon.com
November 10, 2026 at 2:21 AM
Switch Pros SP-9100 8-Switch Panel Power System With Concealed Mounting Hardware #Battery #Waterproof #SolidState #Lighting #PowerSystem
Switch Pros SP-9100 8-Switch Panel Power System With Concealed Mounting Hardware
www.amazon.com
November 9, 2026 at 9:30 PM
CISAがサブネットソリューションPowerSYSTEM Centerの重大な欠陥について警告 #Security Online (Nov 6)
securityonline.info/subnet-solut...
https://securityonline.info/windows-paint-rce-cve-2026-83844-fixed/
securityonline.info
November 9, 2026 at 3:15 AM
Vulnerabilities in Subnet Solutions PowerSYSTEM Center
URL: www.cisa.gov/news-events/...
Classification: Critical, Solution: Official Fix, Exploit Maturity: Not Defined, CVSSv4.0: 9.4
Subnet Solutions PowerSYSTEM Center | CISA
www.cisa.gov
November 4, 2026 at 11:06 AM
CVE-2026-63017
PowerSYSTEM Center does not correctly check a user’s rights, so a user with limited permissions can view or change settings that should be reserved for administrators. This could lead to unauthorized changes or…

Too many irrelevant or confusing CVEs? Use stackflag.com

#CVE #infosec
CVE-2026-63017: PowerSYSTEM Center lets regular user access admin resources
PowerSYSTEM Center does not correctly check a user’s rights, so a user with limited permissions can view or change settings that should be reserved for.
stackflag.com
November 6, 2026 at 2:20 AM
CVE-2026-63774
The report design feature in PowerSYSTEM Center does not properly check the information it receives, so a user who is signed in can trick it into sending its own database commands. This could let the user view,…

Too many irrelevant or confusing CVEs? Use stackflag.com

#CVE #infosec
CVE-2026-63774: PowerSYSTEM Center report designer lets logged-in users run SQL
The report design feature in PowerSYSTEM Center does not properly check the information it receives, so a user who is signed in can trick it into sending.
stackflag.com
November 6, 2026 at 2:20 AM
Switch Pros SP-9100 8-Switch Panel Power System With Concealed Mounting Hardware#Switch#PowerSystem#Lighting#Panel#Automation
Switch Pros SP-9100 8-Switch Panel Power System With Concealed Mounting Hardware
www.amazon.com
November 7, 2026 at 12:58 AM
Switch Pros SP-9100 8-Switch Panel Power System With Concealed Mounting Hardware#Switch#PowerSystem#Lighting#Panel#Automation
Switch Pros SP-9100 8-Switch Panel Power System With Concealed Mounting Hardware
www.amazon.com
November 6, 2026 at 3:38 PM
Latest post from CISA
Subnet Solutions PowerSYSTEM Center
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to execute unauthorized SQL commands and gain access to unauthorized resources. The following versions of Subnet Solutions PowerSYSTEM Center are affected: PowerSYSTEM Center 2020 <=5.29.x (CVE-2026-63017) PowerSYSTEM Center 2024 >=6.0.x|<=6.2.x (CVE-2026-63017, CVE-2026-63774) PowerSYSTEM Center 2026 >=7.0.x|<=7.1.x (CVE-2026-63017, CVE-2026-63774) CVSS Vendor Equipment v3 9 Subnet Solutions PowerSYSTEM Center 2 Vulnerabilities Incorrect Authorization, Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') Background Critical Infrastructure Sectors: Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Canada Vulnerabilities Expand All + CVE-2026-63017 Incorrect authorization in PowerSYSTEM Center allows a low-privileged, authenticated user to access resources normally limited to administrators. Read More 3 Affected Products Subnet Solutions PowerSYSTEM Center 2024 >=6.0.x|<=6.2.x Product Status: known_affected Remediations Mitigation For users who are currently using PowerSYSTEM Center 2024, Subnet Solutions recommends users upgrade to PowerSYSTEM Center 2026 Update 1.1. For assistance in upgrading, users should contact the Subnet Solutions System Integration team or customer support team at (403) 270-8885 or by email at support@subnet.com. If unable to update to the latest version, Subnet Solutions recommends users monitor user activity records to ensure users are following acceptable usage policies of the application. Subnet Solutions also recommends disabling PowerSYSTEM Center Client Access Server users' ability to access the browser's F12 Developer Tools. Subnet Solutions PowerSYSTEM Center 2020 <=5.29.x Product Status: known_affected Remediations Mitigation Subnet Solutions recommends users update to PowerSYSTEM Center 2020 Update 30. For assistance in upgrading, users should contact the Subnet Solutions System Integration team or customer support team at (403) 270-8885 or by email at support@subnet.com. If unable to update to the latest version, Subnet Solutions recommends users monitor user activity records to ensure users are following acceptable usage policies of the application. Subnet Solutions also recommends disabling PowerSYSTEM Center Client Access Server users' ability to access the browser's F12 Developer Tools. Subnet Solutions PowerSYSTEM Center 2026 >=7.0.x|<=7.1.x Product Status: known_affected Remediations Mitigation Subnet Solutions recommends users update to PowerSYSTEM Center 2026 Update 1.1. For assistance in upgrading, users should contact the Subnet Solutions System Integration team or customer support team at (403) 270-8885 or by email at support@subnet.com. If unable to update to the latest version, Subnet Solutions recommends users monitor user activity records to ensure users are following acceptable usage policies of the application. Subnet Solutions also recommends disabling PowerSYSTEM Center Client Access Server users' ability to access the browser's F12 Developer Tools. Additional Metrics Relevant CWE: CWE-863 Incorrect Authorization CVSS Version Base Score Base Severity Vector String 3.1 9 CRITICAL CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H 4.0 9.4 CRITICAL CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H View CVE Details CVE-2026-63774 Insufficient input validation in the PowerSYSTEM Center report designer allows an authenticated user to execute unauthorized SQL commands. Read More 5 Affected Products Subnet Solutions PowerSYSTEM Center 2024 >=6.0.x|<=6.2.x Product Status: known_affected Remediations Mitigation For users who are currently using PowerSYSTEM Center 2024, Subnet Solutions recommends users upgrade to PowerSYSTEM Center 2026 Update 1.1. For assistance in upgrading, users should contact the Subnet Solutions System Integration team or customer support team at (403) 270-8885 or by email at support@subnet.com. If unable to update to the latest version, Subnet Solutions recommends users disable user access to the report designer. Subnet Solutions PowerSYSTEM Center 2020 <=5.29.x Product Status: known_affected Remediations Subnet Solutions PowerSYSTEM Center 2026 >=7.0.x|<=7.1.x Product Status: known_affected Remediations Mitigation Subnet Solutions recommends users update to PowerSYSTEM Center 2026 Update 1.1. For assistance in upgrading, users should contact the Subnet Solutions System Integration team or customer support team at (403) 270-8885 or by email at support@subnet.com. If unable to update to the latest version, Subnet Solutions recommends users disable user access to the report designer. Subnet Solutions PowerSYSTEM Center 2024 >=6.0.x|<=6.2.x Product Status: known_affected Remediations Mitigation For users who are currently using PowerSYSTEM Center 2024, Subnet Solutions recommends users upgrade to PowerSYSTEM Center 2026 Update 1.1. For assistance in upgrading, users should contact the Subnet Solutions System Integration team or customer support team at (403) 270-8885 or by email at support@subnet.com. If unable to update to the latest version, Subnet Solutions recommends users disable user access to the report designer. Subnet Solutions PowerSYSTEM Center 2026 >=7.0.x|<=7.1.x Product Status: known_affected Remediations Mitigation Subnet Solutions recommends users update to PowerSYSTEM Center 2026 Update 1.1. For assistance in upgrading, users should contact the Subnet Solutions System Integration team or customer support team at (403) 270-8885 or by email at support@subnet.com. If unable to update to the latest version, Subnet Solutions recommends users disable user access to the report designer. Additional Metrics Relevant CWE: CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CVSS Version Base Score Base Severity Vector String 3.1 9 CRITICAL CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H 4.0 9.4 CRITICAL CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H View CVE Details Acknowledgments Chinmay Patel of Digital Boundary Group reported these vulnerabilities to CISA. Subnet Solutions reported these vulnerabilities to CISA. Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet . Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics . Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities are not exploitable remotely. Revision History Initial Release Date: 2026-11-03 Date Revision Summary 2026-11-03 1 Initial Publication Legal Notice and Terms of Use
www.cisa.gov
November 3, 2026 at 4:30 PM