And your 6 week probe out time is not too bad - we had a neo console down for... 4 months, and the cryoprobe seems to have died during that period, and theres not even an ETA on *sending it out* for repair, let alone what the repair timeline would be...
And your 6 week probe out time is not too bad - we had a neo console down for... 4 months, and the cryoprobe seems to have died during that period, and theres not even an ETA on *sending it out* for repair, let alone what the repair timeline would be...
onlinelibrary.wiley.com/doi/10.1002/...
onlinelibrary.wiley.com/doi/10.1002/...
Fun thing for my colleague to discover with a $250k cryoprobe.
Fun thing for my colleague to discover with a $250k cryoprobe.
Fun thing for my colleague to discover with a $250k cryoprobe.
R3: “it looks like you used a cryoprobe for all your nmrs -why did you need to run at low temp? Please add some clarification…”
R3: “it looks like you used a cryoprobe for all your nmrs -why did you need to run at low temp? Please add some clarification…”
- CAT Scan
- First Heart Transplant
- First Penile Transplant
- Retinal Cryoprobe
- Smartlock Safety Syringe
- and more...
- CAT Scan
- First Heart Transplant
- First Penile Transplant
- Retinal Cryoprobe
- Smartlock Safety Syringe
- and more...
“E4075 Main gas and backup gas pressure are too close
The main gas pressure (5.62bar) is less than 0.5 bar above the back up gas pressure (5.61bar)”
The pressure from the He cylinder is 25 bars though, any quick remedy?
“E4075 Main gas and backup gas pressure are too close
The main gas pressure (5.62bar) is less than 0.5 bar above the back up gas pressure (5.61bar)”
The pressure from the He cylinder is 25 bars though, any quick remedy?
To which coils in a Bruker TCI cryoprobe are the 4 RF-channels (1H, 2H, 13C, 15N) connected. I was (until recently) convinced that it is inner coil: 1H, 2H; outer coil: 13C,15N. But I received ambiguous info recently. This is important for power limits when 2H and another 13C.
To which coils in a Bruker TCI cryoprobe are the 4 RF-channels (1H, 2H, 13C, 15N) connected. I was (until recently) convinced that it is inner coil: 1H, 2H; outer coil: 13C,15N. But I received ambiguous info recently. This is important for power limits when 2H and another 13C.